Data Sheet

MPU-6000/MPU-6050 Product Specification 
Document Number: PS-MPU-6000A-00 
Revision: 3.4 
Release Date: 08/19/2013 
 43 of 52 
11.4  Assembly Precautions  
11.4.1  Gyroscope Surface Mount Guidelines 
InvenSense MEMS Gyros sense rate of rotation. In addition, gyroscopes sense mechanical stress coming 
from the printed circuit board (PCB). This PCB stress can be minimized by adhering to certain design rules: 
When using  MEMS  gyroscope components  in  plastic  packages,  PCB  mounting  and  assembly  can  cause 
package stress. This package stress in turn can affect the output offset and its value over a wide range of 
temperatures. This stress is caused by the mismatch between the Coefficient of Linear Thermal Expansion 
(CTE) of the package material and the PCB. Care must be taken to avoid package stress due to mounting. 
Traces connected to pads should be as symmetric as possible. Maximizing symmetry and balance for pad 
connection will help component self alignment and will lead to better control of solder paste reduction after 
reflow. 
Any  material  used  in the  surface  mount assembly process  of  the MEMS  gyroscope  should  be free  of 
restricted RoHS elements or compounds. Pb-free solders should be used for assembly.  
11.4.2  Exposed Die Pad Precautions 
The MPU-60X0 has very low active and standby current consumption. The exposed die pad is not required 
for  heat  sinking,  and  should  not  be  soldered  to  the  PCB.  Failure  to  adhere  to  this  rule  can  induce 
performance changes due to package thermo-mechanical stress. There is no electrical connection between 
the pad and the CMOS. 
11.4.3  Trace Routing 
Routing traces or vias under the gyro package such that they run under the exposed die pad is prohibited. 
Routed active signals may harmonically couple with the gyro MEMS devices, compromising gyro response. 
These devices are  designed  with the  drive frequencies as follows: X  = 33±3Khz, Y  = 30±3Khz,  and 
Z=27±3Khz.  To  avoid  harmonic  coupling  don’t  route  active  signals  in  non-shielded  signal  planes  directly 
below, or above the gyro package. Note: For best performance, design a ground plane under the e-pad to 
reduce PCB signal noise from the board on which the gyro device is mounted. If the gyro device is stacked 
under an adjacent PCB board, design a ground plane directly above the gyro device to shield active signals 
from the adjacent PCB board.  
11.4.4  Component Placement 
Do not place large insertion components such as keyboard or similar buttons, connectors, or shielding boxes 
at a distance of less than 6 mm from the MEMS gyro. Maintain generally accepted industry design practices 
for component placement near the MPU-60X0 to prevent noise coupling and thermo-mechanical stress. 
11.4.5  PCB Mounting and Cross-Axis Sensitivity 
Orientation errors of the gyroscope and accelerometer mounted to the printed circuit board can cause cross-
axis  sensitivity  in  which  one  gyro  or  accel  responds  to  rotation  or  acceleration  about  another  axis, 
respectively. For  example, the  X-axis gyroscope may  respond  to rotation about  the Y  or Z axes.  The 
orientation mounting errors are illustrated in the figure below. 