Information
Table Of Contents
- A. Overview
- 1. Getting started
- 1.1 The BME688 Gas Sensor
- 1.2 Example: Coffee vs. Normal Air
- 1.3 A Few Things To Keep In Mind
- 1.4 Step 1: Record Normal Air
- 1.5 Step 2: Record Espresso Coffee
- 1.6 Step 3: Record Normal Air Again
- 1.7 Step 4: Record Filter Coffee
- 1.8 Step 5: Import & Label The Data
- 1.9 Step 6: Create New Algorithm and Classes
- 1.10 Step 7: Train And Evaluate The Algorithm
- 1.11 Step 8: Export The Algorithm
- 1.12 Conclusion
- 2. Introduction
- 2.1 What is it about? – An analogy
- 2.2 Why the BME688?
- 2.3 What is a use case for a gas sensor?
- 2.4 What is special about the BME688 gas sensor?
- 2.5 How can I evaluate BME688 performance for a specific use case?
- 2.6 How can I use the results for my product development?
- 3. Glossary
- 3.1 Sensor Board
- 3.2 Measurement Session
- 3.3 Algorithm
- B. Process Steps
- 1. Configure Board
- 1.1 Overview
- 1.2 Board Type
- 1.3 Board Mode
- 1.4 Heater Profile
- 1.5 Duty Cycle
- 1.6 Board Layout
- 2. Record Data
- 2.1 Overview
- 2.2 Start recording
- 2.3 During recording
- 2.4 End recording
- 3. Import Data
- 3.1 Overview
- 3.2 Data Overview
- 3.3 Board ID
- 3.4 Board Type
- 3.5 Board Mode
- 3.6 Session Name
- 3.7 Session Date
- 3.8 Specimen Data
- 4. Collect Specimens
- 4.1 Overview
- 4.2 Label
- 4.3 Comment
- 4.4 Session
- 4.5 Start & End Time
- 4.6 Duration
- 4.7 Cycles Total
- 4.8 Cycles Dropped
- 4.9 Remaining Cycles
- 4.10 Board Configuration
- 4.11 Board ID
- 4.12 Board Type
- 4.13 Board Mode
- 4.14 Show Configuration
- 5. Train Algorithms
- 5.1 Overview
- 5.2 Name
- 5.3 Created
- 5.4 Classes
- 5.5 Class Name & Color
- 5.6 Common Data
- 5.7 Data Balance
- 5.8 Data Channels
- 5.9 Neural Net
- 5.10 Training Method
- 5.11 Max. Training Rounds
- 5.12 Data Splitting
- 6. Evaluate Algorithms
- 6.1 Overview
- 6.2 Confusion Matrix
- 6.3 Accuracy
- 6.4 Macro-averaged F1 Score
- 6.5 Macro-averaged False Positive Rate
- 6.6 Training Data
- 6.7 Test Data
- 6.8 Additional Testing
- 2.1
Bosch Sensortec | BME AI-Studio Documentation 13 | 49
Modifications reserved | Data subject to change
without notice Document number: BST-BME688-AN001-00
2.5 How can I evaluate BME688 performance for a specific use case?
The BME AI-Studio is the perfect tool to support you in the quest of finding out whether a specific use case can be
tackled with the BME688 gas sensor. There are the following degrees of freedom that you can vary within the testing
conditions:
Data recording and testing environment
Heater profile configuration
Duty cycle configuration
Algorithm training parameters
In general, the process can be viewed as a careful exploration and an iterative approach. The following procedure has
proven to be very efficient:
2.5.1 Phase I: Doing the first measurements
In the first phase, you just start recording whatever use case you have in mind. On your way of exploring the use case
more and more, you will gain knowledge and sometimes you have to redo some of the measurements. That is very
normal when exploring new use cases.
Please note
Fabric-new BME boards need to undergo an initial stabilization procedure. Please let the board run for at least 24
hours before recording any meaningful data.
A factory-new BME board comes preconfigured with the heater profile HP-354 and the duty cycle RDC-5-10. This
means you can start right away capturing the first data. As a more advanced user, you might want to configure the