Datasheet

SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE
RANGE
EFFICIENCY (Typ.)INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A
5 ~ 95% RH non-condensing
-40 ~ +85 , 5 ~ 95% RH
± 0.03%/ (0 ~ 55 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
130.7K hrs min. MIL-HDBK-217F (25 )
216*97*40mm (L*W*H)
1.19Kg ; 12pcs/15.3Kg/1.12CUFT
File Name:RSD-300-SPEC 2014-05-07
300W Railway Single Output DC-DC Converter
Features :
R SD-300
s eries
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
ENVIRONMENT
PROTECTION
1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
12V5V
RSD-300B-12RSD-300B-5 RSD-300B-24 RSD-300B-48 RSD-300C-12RSD-300C-5 RSD-300C-24 RSD-300C-48
24V 48V 12V5V 24V 48V
42A 25A42A 12.5A 6.3A
0 ~ 42A 0 ~ 25A0 ~ 42A 0 ~ 12.5A 0 ~ 6.3A
210W 300W210W 300W 302.4W
120mVp-p100mVp-p 150mVp-p 180mVp-p 120mVp-p100mVp-p 150mVp-p 180mVp-p
±2.0%±2.0% ±2.0% ±2.0% ±2.0%±2.0% ±2.0% ±2.0%
±0.3%±0.5% ±0.2% ±0.5% ±0.3%±0.5% ±0.2% ±0.5%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%±1.0% ±1.0% ±1.0%
800ms, 50ms at full load
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
89.5%89% 90% 91.5% 91%90.5%
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
91.5% 92%
14.6A/24V9.7A/24V 14.6A/24V 14.6A/24V
45A/48VDC
7.2A/48V4.8A/48V 7.2A/48V 7.2A/48V
45A/24VDC
Meet IEC60950-1(LVD), EN45545-2:2013
Compliance to EN50155 railway standard
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
/ Input reverse polarity
4000VDC I/O isolation
Cooling by free air convection
Half encapsulated
Built-in constant current limiting circuit
1U low profile 40mm
All using 105 long life electrolytic capacitors
LED indicator for power on
100% full load burn-in test
3 years warranty
13.8 ~ 16.2V5.75 ~ 7V 13.8 ~ 16.2V5.75 ~ 7V27.6 ~ 32.4V 55.2 ~ 64.8V 27.6 ~ 32.4V 55.2 ~ 64.8V
EMC IMMUNITY
EMC EMISSION
HOLD UP TIME (Typ.)
CONTINUOUS
1 SEC.
B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
Protection type : Shut down o/p voltage, re-power on to recover
22.5A 11.3A 5.7A
0 ~ 22.5A 0 ~ 11.3A 0 ~ 5.7A
270W 271.2W 273.6W
RAILWAY STANDARD Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
-40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance