Datasheet
Copyright © 2008-2013 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
, the Cree logo and XLamp
®
are registered
trademarks of Cree, Inc.
3
xlamp xp-e leds
FLUX CHARACTERISTICS (T
J
= 25 °C) - WHITE
The following table provides several base order codes for XLamp XP-E LEDs. It is important to note that the base order
codes listed here are a subset of the total available order codes for the product family. For more order codes, as well
document.
Color
CCT Range
Base Order Codes
Min. Luminous Flux
(lm) @ 350 mA
Order Code
Min. Max. Group Flux (lm)
Cool White 5000 K 10,000 K
Q4 100
Q5 107
R2 114
R3 122
Outdoor
White
4000 K 5300 K
Q4 100
Q5 107
R2 114
R3 122
Neutral
White
3700 K 5300 K
Q3 93.9
Q4 100
Q5 107
80-CRI
White
2600 K 4300 K
P4 80.6
Q2 87.4
Warm
White
2600 K 3700 K
P4 80.6
Q2 87.4
Q3 93.9
85-CRI
White
2600 K 3200 K
N4 62.0
P2 67.2
P3 73.9
P4 80.6
90-CRI
White
2600 K 3200 K
N4 62.0
P2 67.2
P3 73.9
measurements and ±2 on CRI measurements.
Typical CRI for Cool White (5000 K – 10,000 K CCT) is 70.
Typical CRI for Neutral White (3700 K – 5300 K CCT) is 75.
Typical CRI for Outdoor White (4000 K - 5300 K CCT) is 70.
Typical CRI for Warm White (2600 K – 3700 K CCT) is 80.