TEST OPERATION
1 Adjust the air pressure at 5 bar (70 p.s.i.) and connect the
air supply.
2 Without touching the trigger, depress the staple discharge
outlet against the work-piece.
Pull the trigger. (The tool must fire the fastener.)
3 Adjust the air pressure as much as the lowest possible ac-
cording the length of fastener and the hardness of work-
piece.
AIR HOSE CONNECTION
Connect the air chuck to the air plug.
When connecting the air chuck, do not point the staple dis-
charge outlet at any part of your body or at another preson,
and do not touch the trigger.
DRIVING FASTENERS
1 Depress the staple discharge outlet against a place where
you want to drive a staple.
2 Pull the trigger.
CLEARING JAMMED STAPLES
1 Disconnect the air hose.
2 Remove the set of staples from the magazine.
3 Take out the 4 hexagon socket head cap screws from the
magazine and remove the driver guide.
4 Clear the staples jammed inside the nose using a thin iron
bar or a flat-blade screwdriver.
5 Reinstall the driver guide cover, reinsert the set of staples
and bring back the slider unit.
ALWAYS disconnect air supply before clearing jammed fas-
tener.
WARNING
2
1
Trigger
Outlet
Driver
Guide
Flat-blade
screwdriver
Slider Unit