Third Party Verification Claim
Table Of Contents
- Page 12 of 18 -
Report No.: ET-FCC18120028
Tel:(86-755)85259392
Fax: (86-755) 27219460
Web: http://www.etrtest.com
E-mail: etr888@etrtest.com
Address: 2/F, Runzhen Business Building, No.22 Fuhai Road, Fuyong Street Bao'an District, Shenzhen, China.
5.2 Radiated emission
5.2.1 Limits
Limits of radiated emission measurement
Frequency
(MHz)
Class B device
(at 3m) dBμV/m
Class A device
(at 3m) dBμV/m
Detector
30-88 40 49
QP
88-216
43.5
53.5
QP
216-960
46
56.4
QP
960-1000
54
59.5
QP
Above 1000 54 59.5
AV
Above 1000 74 79.5
PK
5.2.2 Test Procedures
The radiated emission tests were performed in the 3 meters.
The EUT was placed on the top of a rotating table 0.8 meters above the ground. The table was
rotated 360 degrees to determine the position of the highest radiation.
The height of the test antenna shall vary between 1m to 4m. Both horizontal and vertical
polarizations of the antenna are set to make the measurement.
If the peak mode measured value compliance with and lower than quasi peak mode limit, the EUT
shall be deemed to meet QP limits and then no additional QP mode measurement performed.
If the peak mode measured value compliance with and lower than average mode limit, the EUT
shall be deemed to meet average limits and then no additional average mode measurement
performed.
For the actual test configuration, please refer to the related item – EUT test photos.
5.2.3 Test Setup
5.2.4 Test Result