Report No.: ET-FCC18120028
Tel:(86-755)85259392
Fax: (86-755) 27219460
Web: http://www.etrtest.com
E-mail: etr888@etrtest.com
Address: 2/F, Runzhen Business Building, No.22 Fuhai Road, Fuyong Street Bao'an District, Shenzhen, China.
5 Test Results
5.1 Conducted emission
5.1.1 Limits
Frequency
(MHz)
Class A (dBμV)
Class B (dBμV)
Quasi-peak
Average
Quasi-peak
Average
0.15 -0.5
79
66
66 - 56 *
56 - 46 *
0.5 -5 73 60 56 46
5 -30
73
60
60
50
Note 1: the tighter limit applies at the band edges.
Note 2: the limit of " * " marked band means the limitation decreases linearly with the logarithm of
the frequency in the range.
5.1.2 Test Procedures
The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the
power mains through a line impedance stabilization network (LISN). All other support equipment
powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the
measuring instrument.
Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
forth in the center forming a bundle 30 to 40 cm long.
I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall length
shall not exceed 1 m.
LISN is at least 80 cm from nearest part of EUT chassis.
For the actual test configuration, please refer to the related Item – photographs of the test setup.
5.1.3 Test Setup
5.1.4 Test Result