Section 6 Troubleshooting
Indicator Lights
Alarm/Fault
Condition
LED 1
(UV Controller
Status)
LED 2
(UV Lamp
Status)
Audio Indicator
Status
Notes
UV Lamp Ignition/Run
Fault
Red Flashing Red Beeping
1. Unplug UV system from main power supply.
2. Check for secure lamp connection.
3. Restore power to UV system.
4. If failure message repeats, replace UV lamp.
Audible alarm may be silenced for 24 Hours.
UV Lamp Near End of
Life Warning
Green Yellow Off Warning: Lamp will require replacement shortly.
UV Lamp At End of Life
Fault
Green Flashing Red Chirp
1. Follow instructions in manual to replace lamp.
Warning Chirp may be silenced for 7 Days.
UV Lamp EOL
Exceeded Fault
Green Flashing Red Chirp
1. Follow instructions in manual to replace lamp.
Warning Chirp may be silenced for 24 Hours.
AC Voltage out of
Range
Flashing Red Flashing Red Beeping
When the AC voltage is back in range (>93V or <265V) the
alarm cancels and normal operation is resumed.
Audible alarm may be silenced temporarily.
UV Controller Fault Flashing Red Red Beeping
1. Unplug UV system from main power supply.
2. Allow 30 seconds for unit to fully power down.
3. Restore power to UV system.
4. If failure message repeats, replace controller.
Audible alarm may be silenced for 24 Hours.
Symptom Possible Cause Possible Solution
No power
GFCI and/or breaker tripped Reset GFCI and/or breaker
Transient voltage surge suppressor (TVSS) damaged Replace TVSS
Controller damaged Replace controller and use a TVSS
GFCI or breaker repeatedly
trips
Connection between lamp and lamp plug is wet
Clean and dry lamp pins and lamp plug, check unit for leaks
or condensation
Short-circuit in the electrical assembly Replace controller
Leak at inlet or outlet Threaded pipe fittings are leaking Clean threads, reseal with Teflon tape and retighten
Leak detected from area of UV
chamber
Condensation of moist air on cold chamber (slow
accumulation)
Control humidity or relocate unit
O-ring damaged, deteriorated or incorrectly installed Inspect and replace if deteriorated
Lamp/sleeve assembly not properly installed (too tight or not
tight enough)
Tighten assembly hand-tight
Alarm Refer to Section 5. Refer to Section 5.
System is operating but water
tests reveal bacterial
contamination
Equipment downstream of UV system is acting as a breeding
ground for pathogens
Ensure UV is the last piece of treatment equipment
Pathogens are residing in the distribution lines post-UV
Ensure all distribution lines have been disinfected with
chlorine. Refer to Section 3.2.
Recontamination from pipe dead-ends
Remove any pipe dead-ends and flush with chlorine. Refer to
Section 3.2.
Lamp timer does not read
anything
Unit is unplugged. Plug unit into AC power outlet
No power at AC power outlet Replace fuse or reset breaker
Power cord is damaged Replace power cord
Power surge caused damage to electrical assembly Replace controller and use a surge protector (TVSS)
Troubleshooting
Sección 2 Información general
Figura 1 Componentes del sistema
Elemento Descripción N.º pieza
1 Cámara UV (incluye abrazaderas de cámara y abrazadera de anillo) -
2 Vaina tubular (incluye juntas tóricas) 602732
3 Junta tórica -
4 Lámpara (incluye juntas tóricas) 602805
5 Perno de la vaina tubular 602665
6 Abrazadera de montaje del controlador -
7 Ficha de referencia -
8 Controlador (incluye abrazadera de montaje del controlador, ficha de referencia) 650733R-003
9 Conector de lámpara -
10 Cable de alimentación (120 V) 602636
4
2
1
8
7
9
10
5
6
3
Información general
12
33