XP2300IH INVERTER GENERATOR User Manual REV: XP2300iH-02032021 This manual provides information regarding the operation and maintenance of these products. We have made every effort to ensure the accuracy of the information in this manual. We reserve the right to change this product at any time without prior notice. 5800 Ontario Mills Pkwy Ontario, CA 91764 USA www.DuroMaxpower.
CONTENTS 1. Introduction Introduction ..................................................................................................................... 6 General Safety Procedures ............................................................................................ 8 Quick Start Guide (Gasoline) ....................................................................................... 14 Quick Start Guide (Propane).....................................................................................
CONTENTS 5. Maintenance and Care Maintenance Schedule................................................................................................... 40 Maintenance Log ........................................................................................................... 41 Checking the Oil ............................................................................................................. 42 Changing the Oil..................................................................................
THE DuroMax WAY The DuroMax Way is more than just a brand, it is our understanding and appreciation of just how important power can be to someone without it… DuroMax FOR HOME Electricity in our home not only provides comfort but safety as well. From keeping the heat or A/C on to keeping our food cold, power is essential to our daily lives. Inevitability when disaster strikes and we are left without power for a prolonged period of time, our way of life is put at risk.
INTRODUCTION DuroMax Power Equipment is headquartered in Ontario, California and is the industry’s leader in Dual Fuel portable generator technology. In addition to a full assortment of portable generators ranging from digital inverters to large 15,000-watt portable standby units, their product line includes pressure washers, engines, pumps, and accessories. The foundation of our company is built on quality, reliability, durability, and customer service.
GENERAL SAFETY PROCEDURES SAFETY ALERT SYMBOL The safety alert symbol is used with one of the safety words (DANGER, CAUTION, or WARNING) to alert you of hazards. Please pay attention to these hazard notices both in this manual and on the generator. Please familiarize yourself with the following safety symbols and words: ● DANGER: Indicates a hazard that will result in serious injury or death if instructions are not followed.
WARNING: This generator may emit highly flammable and explosive gasoline vapors, which can cause severe burns or even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline. ● Do not operate near an open flame. ● Do not smoke near the generator. ● Always operate on a firm, level surface. ● Always turn the generator off before refueling. ● Allow generator to cool for at least 2 minutes before removing the fuel cap. Loosen cap slowly to relieve pressure in the tank.
UNIT AND PURCHASE INFORMATION Serial Number Serial Number The serial number is located on the engine block, above and to the left of the oil fill. Serial number format The serial number will be shown in two parts. The engine model, followed by the serial number. Engine Model: _____________________________________________ Serial Number: _____________________________________________ STAPLE RECEIPT HERE A purchase receipt may be necessary for warranty parts or service in the future.
As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, odorless threat. Visit takeyourgeneratoroutside.com for more information.
QUICK START The quick start of your generator is the minimum necessary setup that will get you going as soon as possible. Be sure to read the instructions for full setup instructions.
QUICK START GUIDE (GASOLINE) 1. Add oil The oil fill cap is located on the lower engine block to the right of the recoil start housing. Remove the oil fill cap and fill with 10w30 oil. 2. Add gasoline The fuel cap is located on top of the fuel tank. Fill the tank with fresh unleaded gasoline 87 octane or higher. The tank is full when you see fuel in the bottom of the fuel filter cup. DO NOT overfill the tank. Gasoline fuel Fuel 3.
6. Turn start switch on The start switch is located on the left side of the front power panel next to the low Idle. Press the switch up to the start position to allow the generator to start. Lowidle Idleoff off 7. 6. Turn low The Low low Idle Idle is is located located on on the the left left side of the front power panel, next to to the thebreaker. parallel outlet. Flip theFlip switch the down switchtodown disable to ECO-Mode disable ecowhen modestarting when starting the generator. the generator.
QUICK START GUIDE (PROPANE) 1. Add oil The oil fill cap is located on the lower engine block to the right of the recoil start housing. Remove the oil fill cap and fill with 10w30 oil. Add gasoline propane hose 2. Connect The LPG fuel cap Inletisislocated locatedon ontop theof bottom the fuel of tank. the fuel Fillselection the tank with fresh panel. Connect unleaded the propane gasolinehose 87 octane to both or the higher. inletThe andtank the is full when propane tank.
Lowidle Idleoff off 6. Turn low The Low low idle Idle is is located located on on the the left left side of the front power panel, next to to the thebreaker. parallel outlet. Flip theFlip switch the down switchtodown disable to ECO-Mode disable ecowhen modestarting when starting the generator. the generator. Turn Start Switch on 7. Decompress The Thedecompression Start Switch is valve located is located on the on leftthe side propane of the hose.
GENERATOR COMPONENTS 4. Recoil Start 6. Fuel Valve 5. Fuel Cap 7. Handle 8. Power Panel 3. Fuel Switch 2. Choke 1. Wheels 9. LPG Inlet 1. Wheels - Solid wheels allow for easy transportation over any terrain. 2. Choke - Assist the generator when starting on gasoline. 3. Fuel Switch - GAS/LPG Valve that changes the fuel into the engine. 4. Recoil Start - Pull the recoil start handle to spin the engine during start-up. 5. Fuel Cap - Allows access to fill the gasoline tank. 6.
12. USB Ports 13. Multimeter 11. Start Up Switch 10. Low Idle 14. Breaker 15. Ground Lug 18. Parallel Ports 17. 3-Prong Twist-Lock 16. 120v GFCI 13. Multimeter - Provides information of Hours Run, Voltage, Hertz, current load on the generator measured in kW, and the amount of gasoline in the gas tank. 14. Breaker - Resettable switch that protects the generator from electrical overload. 15. Ground Lug - Grounds the generator to the earth. (may be required by code) 16.
PACKAGE CONTENTS Your generator comes with the items listed below. Please check to see that all of the following items are included with your generator. Double Sided Screw Driver Phillips and slot blade screwdriver used for generator maintenance. Oil Funnel w/ hose Used to add oil to the generator without messy spills. Spark Plug Wrench Used in spark plug maintenance, inspection, and installation. ● Note: Actual tools may differ in appearance or design from image shown.
GENERATOR SETUP Proper setup of your generator will get you going as soon as possible while making sure you and your equipment are safe and cared for.
GENERATOR SETUP (CONTINUED) Step 1 - Adding Oil The generator requires engine oil to operate properly. The generator, when new from the package, contains no oil in the crankcase*. You must add the proper amount of oil before operating the generator for the first time. This amount is equal to the oil capacity of the engine crankcase: Model Number XP2300iH Engine Oil Capacity 13 fl. oz (0.4L) WARNING: Do not apply engine oils with additives or 2-stroke gasoline engine oils.
Step 2 - Adding Gasoline (Optional) Add gasoline a. Make sure the generator is on a level surface. b. Unscrew gas cap and set aside (NOTE: the gas cap may be tight and hard to unscrew). c. Slowly add unleaded gasoline to the fuel tank. Be careful not to overfill. The fuel gauge on the digital display indicates how much gasoline is in the generator’s gas tank. d. Replace fuel cap and wipe up any spilled gasoline with a dry cloth. Model Number XP2300iH Gas Tank Capacity 1.1 US Gal. (4.
GENERATOR SETUP (CONTINUED) Step 4 - Grounding the Generator Attach grounding wire a. Ground the generator by tightening the grounding nut against a grounding wire. b. Connect the other end to a copper or brass grounding rod that’s driven into the earth. A generally acceptable grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. Grounding codes can vary by location. Please contact a local electrician to check the grounding regulations for your area.
STARTING THE GENERATOR If this is not your first time using the generator there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point, you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP” If you have not yet read this section, go back and read it now.
BEFORE YOU START YOUR GENERATOR Step 1 - Check the oil Check the oil The generator is equipped with an automatic shutoff to protect it from damage due to low oil. Nonetheless, you should check the oil level of the engine before each use to ensure that the engine crankcase has a sufficient amount. To check the oil level: 26 a. Make sure the generator is on a level surface. b. Remove the oil cover. c. Unscrew the oil filler/dipstick cap. d.
Step 2 - Check the gas level (Optional) Check fuel level If running the engine on gasoline check to see that there is sufficient gasoline in the fuel tank. The fuel gauge on the digital display will indicate how much fuel is in the gas tank. DANGER 1.5” DO NOT OVERFILL THE GAS TANK OVERFILLING CAN RESULT IN A FIRE, EXPLOSION, OR DEATH. WARNING: Gasoline and gasoline fumes are highly flammable. ● Do not fill the tank near an open flame.
STARTING THE GENERATOR Starting the generator using gasoline 1. Select gasoline fuel The fuel selector is located on the top of the fuel selection panel. Turn the selector counterclockwise to select gasoline. 2. Turn gas valve on The gas valve is located on the gas cap. Rotate the valve clockwise to the ON position. 3. Pull out choke Pull out the choke lever to allow more fuel into the engine for starting. 4.
5. Turn low idle off The low idle is located on the left side of the front power panel. Flip the switch down to disable eco mode when starting the generator. 6. Pull the recoil start The recoil start is located above the fuel panel. Pull the recoil start briskly to start the generator. 7. Push in choke Push in the choke lever to allow the engine to get more air for normal operation. 8. Connect devices Connect your devices to the receptacles on the front panel. Start with the largest loads first.
STARTING THE GENERATOR (CONTINUED) Starting the Generator Using Propane 1. Connect propane hose The LPG inlet is located on the bottom of the fuel selection panel. Connect the propane hose to both the inlet and the propane tank. Open the propane tank. 2. Select LPG fuel The fuel selector is located on the top of the fuel selection panel. Turn the selector clockwise to select propane. 3. Turn gas valve off The gas valve is located on the gas cap. Rotate the valve counter clockwise to the OFF position. 4.
5. Turn low idle off The low idle is located on the left side of the front power panel. Flip the switch down to disable eco mode when starting the generator. 6. Decompress The decompression valve is located on the propane hose. Press the button for 3 - 5 seconds to release any air int he line. 7. Pull the recoil start The recoil start is located above the fuel panel. Pull the recoil start briskly to start the generator. 8. Connect devices Connect your devices to the receptacles on the front panel.
STARTING THE GENERATOR (CONTINUED) Starting the Generator Using Propane WARNING: WHEN USING THE GENERATOR WITH LPG, MAKE SURE THERE IS NO POSSIBLE IGNITION SOURCE CLOSE TO THE GENERATOR. 1. Before using, make sure all of the LPG connectors and hoses are well connected and sealed. 2. Connect electrical devices to the generator ONLY after the engine runs smoothly. (There may be remnant gasoline in the carburetor; this can cause unsteady engine performance for several minutes) 3.
USING THE GENERATOR If this is not your first time using the generator, there are still steps you should take to prepare it for operation each time you use it. IMPORTANT: At this point, you should be familiar with the procedures described in the first portion of this section entitled “GENERATOR SETUP”; if you have not yet read this section, go back and read it now.
USING THE GENERATOR AC Usage ● You may connect electrical devices running on AC current according to their wattage requirements. ● The chart below shows the rated and surge wattage of your generator according to its model number. ● The rated wattage corresponds to the maximum wattage the generator can output on a continuous basis. ● The surge wattage corresponds to the maximum amount of power the generator can output for a short period of time.
Tool or Appliance Rated (Running) Watts Additional Surge Watts Electric water heater (40 gal) 4000 0 Hot plate 2500 0 Radial arm saw 2000 2000 Electric Stove 1500 0 Circular Saw 1500 1500 Air compressor (1 HP) 1500 3000 Window air conditioner 1200 1800 Miter saw 1200 1800 Microwave 1000 2000 Well water pump 1000 1500 Reciprocating saw 960 1040 Sump pump 800 1200 Refrigerator freezer 800 1200 Furnace blower 800 1300 Computer 800 0 Electric drill 600 900 Tele
USING THE GENERATOR (CONTINUED) Connecting a load to the generator NOTE: Be sure to attach devices to the correct receptacle (outlet). ● 120v devices can be directly connected to the 120v ONLY receptacles. CAUTION: Do not connect 50Hz or 3-phase loads to the generator. 1. Plug in devices Plug in devices to the appropriate receptacle. 2. Turn on connected devices Start or turn on appliances starting with the biggest loads first.
Choosing the right power cord Long or thin cords can drain the power provided to an electrical device by the generator. When using such cords, allow for a slightly higher rated wattage requirement for the electrical device. See table below for recommended cords based on the power requirement of the electrical device. DEVICE REQUIREMENTS WIRE GAUGE BY LENGTH (ft.
USING THE GENERATOR (CONTINUED) Parallel Usage 1. Connect Ground Connect one side of the green cable to the ground bolt found in the lower right corner of the panel of generator 1. 2. Connect Positive Connect the corresponding red cable to the red parallel port on the front panel of generator 1. 3. Connect Negative Connect the corresponding black cable to the black parallel port on the front panel of generator 1. 4. Repeat on Generator 2 Repeat steps 1 - 3 on generator 2.
MAINTENANCE AND CARE Proper maintenance and storage of your generator are essential to ensure trouble-free use of your generator when you need it. By following the maintenance and care requirements, you can keep your generator running smoothly and efficiently for years to come.
MAINTENANCE AND CARE Proper routine maintenance of your generator is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. WARNING: Improper maintenance, or failure to correct a problem before operation, can cause a malfunction in which you can be seriously injured or killed. Always follow the inspection, maintenance recommendations, and schedules in this instruction manual. ● Make sure the engine is off before you begin any maintenance or repairs.
MAINTENANCE LOG Date Generator Hours Maintenance Performed 41
MAINTENANCE AND CARE (CONTINUED) Checking the oil Check the oil The generator is equipped with an automatic shutoff to protect it from damage due to low oil. Nonetheless, you should check the oil level of the engine before each use to ensure that the engine crankcase has a sufficient amount. To check the oil level: 42 a. Make sure the generator is on a level surface. b. Unscrew the oil filler/dipstick cap. c. With a dry cloth, wipe the oil off of the stick on the inside of the cap. d.
Changing the oil Worn out or dirty oil does not cool the generator properly and can lead to catastrophic engine damage. In addition to regular oil changes, it is necessary to drain the oil from the crankcase if it has become contaminated with water or dirt. 1. Remove drain cover Remove the oil drain covers and dipstick. 2. Drain oil Drain oil by tipping the generator into an approved oil disposal container. Contact your local auto parts store for information on oil disposal. 3.
MAINTENANCE AND CARE (CONTINUED) Cleaning the air filter Routine maintenance of the air cleaner helps maintain proper airflow to the carburetor. Check that the air cleaner is free of excessive dirt after every use. Note: Improper maintenance may cause less air to enter the engine or dirty air to enter the engine causing overheating and engine wear. 1. Remove the filter cover Release the clips on the top and bottom of the cover and move the filter cover to allow access to the element. 2.
4. Dry cleaner element Pat dry on a dry cloth and allow the elements to dry completely. 5. Add engine oil to elements Soak the dry elements in a small amount of engine oil. Ring out any excess oil. 6. Replace elements in casing Replace the sponge-like elements in the air cleaner casing and replace the cover.
MAINTENANCE AND CARE (CONTINUED) Spark Plug Maintenance SPARK PLUG CONSULT MANUAL BEFORE REMOVING The spark plug is important for proper engine operation. A good spark plug should be intact, free of deposits, and properly gapped. Improper maintenance may cause reduced fuel economy, misfires, trouble starting, or damage to the spark plug threads. 1. Remove spark plug cap Pull on the spark plug cap to remove it. 2.
4. Measure plug gap Measure the plug gap with a gauge. The gap should be 0.7-0.8 mm (0.028-0.031 in). 5. Clean and re-gap If you are re-using the spark plug, use a wire brush to clean any dirt from around the spark plug base and then re-gap the spark plug. 6. Install spark plug Screw the spark plug back into its place on the generator using the spark plug wrench. 7. Replace spark plug cap Replace the spark plug cap.
MAINTENANCE AND CARE (CONTINUED) Storage and Transportation CAUTION: Never place any type of storage cover on the generator while it is still hot. When transporting your generator: ● Disconnect the spark plug. ● Do not obstruct any ventilation openings & keep the generator in a cool dry area. Storage Period Storage Preparation If you plan on starting the same day. 1. 2. 3. Allow the unit to run 3 - 5 minutes. Turn off the start switch. Store. If you plan on starting the unit again within 30 days. 1.
SPECIFICATIONS AC Rated Wattage (Gasoline) 1800W AC Rated Wattage (Propane) 1700W AC Surge Wattage (Gasoline) 2300W AC Surge Wattage (Propane) 2150W AC Rated Voltage 120V AC Rated Frequency 60 Hz AC Phase Single DC Voltage 5V DC Amperage 3A Engine Type 4-Stroke OHV Forced-Air Ignition System Non-Contact Transistor Displacement 79.8cc Starting Type Electric Fuel Tank Capacity 1.1 US Gal. Oil Capacity 13 fl. oz. (0.4L) Run Time @ 50% (Gasoline) 11 hr.
TROUBLESHOOTING This section of the manual is to help you troubleshoot problems with your generator.
TROUBLESHOOTING Mode Description Engine switch is in the OFF position. Turn engine switch to the ON position. Stale gasoline or water in gasoline. Drain entire system and refill with fresh fuel. Engine is out of fuel Add fuel Fuel is old or contaminated Change fuel Spark Plug is dirty Clean spark plug Spark Plug is broken Replace spark plug Generator is not level Move generator to a level surface Oil is low.
WARRANTY 3-year Warranty All DuroMax Power Equipment warrant the original purchasers to a 3-year Parts Warranty (Residential Use ONLY: Unusually heavy or commercial use is covered for a period of 1-year) in the event of failure due to defects in electrical or mechanical components. Freight on any items submitted for replacement or repair under the Warranty is the responsibility of the equipment owner. This warranty is non-transferable and only valid to the original purchaser.
maintenance listed in your owner’s manual. DuroMax Power Equipment recommends that you retain all receipts covering maintenance on your small off-road engine, but DuroMax Power Equipment cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance.
WARRANTY (CONTINUED) Subsection (4) below. Any such part repaired or replaced under the warranty must be warranted for the remaining warranty period. (2) Any warranted part that is scheduled only for regular inspection in the written instructions required by subsection(d)must be warranted for the warranty period defined in Subsection(b) (2). A statement in such written instructions to the effect of “repair or replace as necessary” will not reduce the period of warranty coverage.
Exhaust Emission Warranty Parts List. (1) Fuel Metering System (i) Carburetor and internal parts (and/or pressure regulator or fuel injection system). (ii) Air/fuel ratio feedback and control system. (iii) Cold start enrichment system. (iv) Fuel tank. (2) Air induction system (i) Controlled hot air intake system. (ii) Intake manifolds. (iii) Air filter. (3) Ignition System (i) Spark Plugs. (ii) Magneto or electronic ignition system. (iii) Spark advance/retard system.
CUSTOMER SERVICE DuroMax Power Equipment is committed to ensuring that our products perform when they need to. Our generators are your lifeline in the event of an emergency. Should you have any problems, please contact our customer service department: DuroMax POWER EQUIPMENT 5800 Ontario Mills Parkway Ontario, CA 91764 Customer Service: 844-DuroMax Customer Service Hours: 8-5 pm PST Website: www.DuroMaxpower.com Email: customerservice@DuroMaxpower.
5800 Ontario Mills Parkway Ontario, CA 91764 United States 844-DuroMax REV: XP2300iH-02032021