Installation Guide

MAINTENANCE
1. YOUR ZURN FAUCET HAS A HIGHLY POLISHED NICKEL CHROME PLATED FINISH. CLEAN WITH SOAP AND WATER
OR A MILD CLEANER WHICH IS SAFE FOR CHROME PLATING. DO NOT USE ACIDS OR TOILET BOWL CLEANER AS
THEY WILL DAMAGE THE FINISH.
2. AQUASPEC FAUCETS CONTAIN CERAMIC MIXING CARTRIDGES WHICH REQUIRE NO MAINTENANCE. TO REMOVE
AND REPLACE THE CARTRIDGE:
2.1. REMOVE HOT/COLD INDEX BUTTON (ITEM #1C) BY CAREFULLY PRYING LOOSE FROM UNDERSIDE OF HANDLE
(ITEM #1A)
2.2. LOOSEN SET SCREW (ITEM # 1B) IN HANDLE
2.3. REMOVE HANDLE FROM CARTRIDGE STEM
2.4. LOOSEN AND REMOVE DOMED CARTRIDGE FLANGE (ITEM # 2)
2.5. LOOSEN AND REMOVE CARTRIDGE RETAINING NUT (ITEM #3)
2.6. PULL CERAMIC MIXING CARTRIDGE (ITEM #4) BY PULLING ON STEM WHILE WIGGLING FROM SIDE-TO-SIDE
2.7. INSTALL NEW CARTRIDGE USING THE ALIGNMENT PINS FOR PROPER ORIENTATION AND PROPER SEATING IN
THE FAUCET BODY.
2.8. REINSTALL HANDLE ASSEMBLY BY REVERSING STEPS 2.1 THROUGH 2.5.
3. TEMPERATURE LIMIT ADJUSTMENT – THE Z82200 FAUCET MAY BE ADJUSTED TO LIMIT THE MAXIMUM OPERATING
TEMPERATURE.
3.1. REMOVE CERAMIC MIXING CARTRIDGE (ITEM #4) PER MAINTENANCE INSTRUCTIONS 2.1 THROUGH 2.6 ABOVE.
3.2. REMOVE RED TEMPERATURE LIMIT RING FROM BLUE MIXING CARTRIDGE.
3.3. ROTATE RED TEMPERATURE LIMIT RING CLOCKWISE TO INCREASE MAXIMUM TEMPERATURE OR COUNTER-
CLOCKWISE TO DECREASE MAXIMUM TEMPERATURE. RED TEMPERATURE LIMIT RING IS MARKED WITH
ARROWS AND +/- TO INDICATE DIRECTION OF ROTATION AND EFFECT ON MAXIMUM TEMPERATURE.
3.4. REPLACE RED TEMPERATURE LIMIT RING IN DESIRED ORIENTATION.
3.5. REINSTALL HANDLE ASSEMBLY BY REVERSING STEPS 2.1 THROUGH 2.5.
3.6. TEST MAXIMUM TEMPERATURE FOR ACCEPTABILITY AND REPEAT STEPS 3.1 THROUGH 3.5 IF NECESSARY.
REPLACEMENT PARTS
G63237 SINGLE CONTROL HANDLE ASSEMBLY
G63241 MOUNTING COMPONENTS FOR SINGLE CONTROL
80242001 CERAMIC MIXING CARTRIDGE
G65506 4” COVER PLATE
G65514 8” COVER PLATE
PAGE 2 OF 3
Trouble Shooting Guide
Problem Cause Solution
FAUCET LEAKS FROM CARTRIDGE RETAINING NUT REMOVE FAUCET HANDLE.
UNDER FAUCET HANDLE TOO LOOSE TIGHTEN CARTRIDGE
ALL SUPPLIES ARE ON. RETAINING NUT. DO NOT
OVER TIGHTEN. TIGHTEN UNTIL
NUT IS SNUG.
NO WATER COMES OUT REMOVE AERATOR.
OF FAUCET SPOUT. ALL AERATOR IS CLOGGED REMOVE DEBRIS AND
SUPPLIES ARE ON. REINSTALL AERATOR.
WATER DEFLECTS AT AN REMOVE AERATOR.
ANGLE FROM THE AERATOR HAS DEBRIS REMOVE DEBRIS AND
FAUCET SPOUT REINSTALL AERATOR.
Form # CF1556 Date: 12/30/10
C.N. No. 127255 Rev.