User manual
Table Of Contents
- Chapter 1 System Requirement
- Chapter 2 Network Connection
- Chapter 3 Access to the Network Camera
- Chapter 4 Wi-Fi Settings
- Chapter 5 Live View
- Chapter 6 Network Camera Configuration
- 6.1 Configuring Local Parameters
- 6.2 Configuring Time Settings
- 6.3 Configuring Network Settings
- 6.4 Configuring Video and Audio Settings
- 6.5 Configuring Image Parameters
- 6.6 Configuring and Handling Alarms
- 6.6.1 Configuring Motion Detection
- 6.6.2 Configuring Tamper-proof Alarm
- 6.6.3 Configuring External Alarm Input
- 6.6.4 Configuring Alarm Output
- 6.6.5 Handling Exception
- 6.6.6 Email Sending Triggered by Alarm
- 6.6.7 Configuring Snapshot Settings
- 6.6.8 Face Detection
- 6.6.9 Configuring Other Alarms
- 6.6.10 Arming or Disarming the Camera
- Chapter 7 Storage Settings
- Chapter 8 Playback
- Chapter 9 Log Searching
- Chapter 10 Others
- Appendix
User Manual of Network Camera
89
1. Enter RS-232 Port Setting interface:
Configuration> Advanced Configuration> System > RS232
Figure 10-16 RS-232 Settings
Note: If you want to connect the camera by the RS-232 port, the parameters of the
RS-232 should be exactly the same with the parameters you configured here.
2. Click to save the settings.
10.8 RS-485 Settings
Purpose:
The RS-485 serial port is used to control the PTZ of the camera. The configuring of
the PTZ parameters should be done before you control the PTZ unit.
Steps:
1. Enter RS-485 Port Setting interface:
Configuration> Advanced Configuration> System > RS485
Figure 10-17 RS-485 Settings
2. Set the RS-485 parameters and click to save the settings.
By default, the Baud Rate is set as 9600 bps, the Data Bit is 8, the stop bit is 1 and
the Parity and Flow Control is None.
Note: The Baud Rate, PTZ Protocol and PTZ Address parameters should be exactly
the same as the PTZ camera parameters.