Product Manual

System Maintenance - Replacing DI Resin
NOTE: Unger does not recommend the use of bulk resin with nLite HydroPower
systems. The use of bulk resin, with its widely varying properties, may cause
damage to the system due to excessive expansion when water is introduced.
Overlling the system will also cause damage.
Unger’s pre-measured QuickChange
TM
Replacement Resin Bags are designed to allow
controlled resin expansion within a designed safety limit.
ungerglobal.com
Installation &
Operating Instructions
11
SHUT OFF FEED WATER SUPPLY
• Depress yellow lever on system head assembly.
• Turn On/Off Valve to “OFF” position.
• Disconnect waterfed wash pole hose.
RELEASE SYSTEM HEAD ASSEMBLY
• While continuing to depress the yellow lever,
use a counterclockwise quarter-turn to release
system head assembly; remove and set aside.
• Reach into housing and remove exhausted resin
by hand; discard according to local regulations.
REPLACE RESIN
• Drop in new resin bag(s) by hand – be sure to
seat bags with zip-tie facing up. Pat down bag by
hand to ensure seated properly.
• Inspect system head assembly: O-ring
and FloWater
TM
distribution filter are in
good condition.
RE-INSTALL DI SYSTEM HEAD ASSEMBLY
Push down rmly, then quarter-turn clockwise.
RECONNECT WATERFED WASH POLE TUBING
• Open any valves in the output. Ensure all valves
in the output are open.
Turn on water supply valve
TEST SYSTEM TDS