User Manual
1
2
3
4
6
7
9
10
5
8
Hz
P/N:110401108829X
Preface
Thank you for purchasing the new AC clamp meter. In order to use 
this product safely and correctly, please read this manual thoroughly, 
especially the Safety Instructions part. 
After reading this manual, it is recommended to keep the manual at 
an easily accessible place, preferably close to the device, for future 
reference. 
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material 
and workmanship within one year from the purchase date. This warranty 
does not apply to damages caused by accident, negligence, misuse, 
modification, contamination or improper handling. The dealer shall 
not be entitled to give any other warranty on behalf of Uni-T rend. If 
you need warranty service within the warranty period, please contact 
your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental 
or subsequent damage or loss caused by using this device. As some 
countries or regions do not allow limitations on implied warranties and 
incidental or subsequent damages, the above limitation of liability may 
not apply to you.
UT201+/UT202+/UT202A+ 
AC Clamp Meter User Manual
I. Overview
The UT201+, UT202+, and UT202A+ are true RMS AC clamp meters. 
They are designed according to EN61010-1 and CAT II 600V/
CAT III 300V safety standards. These meters come with full-featured 
protection which ensures users a safe and reliable measurement 
experience. Aside from all the normal features of AC clamp meter, 
these meters also include high voltage frequency measurement, fast 
capacitance measurement, audio visual NCV detection, and plenty 
of additional safety features. UT202A+ also comes with live/neutral 
wire detection.
II. Features
• True RMS measurement
• Audio visual NCV detection
• Maximum measurable voltage: 600V; 
• High voltage frequency range: 10Hz~10kHz
• Current (UT201+/UT202+: 400A, UT202A+: 600A) frequency 
 response: 50Hz~100Hz; current frequency measurement function
• Large capacitance (4mF) and temperature measurement (UT202+ only)
• Very large capacitance (60mF), low voltage frequency (10MHz), 
 and live/neutral wire measurement functions (UT202A+ only)
• Large LCD and fast refresh rate (3 times/s)
• Response time for capacitance measurement: less than 3s for  1mF; ≤
 about 6s for ≤10mF; about 8s for  60mF≤ 
• Full-featured false detection protection for up to 600V (30kVA) energy 
 surge; overvoltage and overcurrent alarm functions
• The power consumption of the meter is about 1.8 mA. The circuit 
 has an automatic power saving function. The consumption in sleep 
 state is <11uA, which effectively extends the battery life to 400 hours.
 Warning: Before using the meter, please read the Safety 
  carefully. Instructions 
III. Accessories
Open the package box and take out the meter. Please double check 
whether the following items are missing or damaged.
a) User manual ---------------------------------------------- 1 pc
b) Test leads 1 pair ------------------------------------------------- 
c) K-type temperature probe (UT202+ only) 1 pc --------- 
d) Cloth bag 1 pc  -------------------------------------------------- 
If any of the above is missing or damaged, please contact your supplier 
immediately.
IV. Safety Instructions
The meter is designed according to EN61010-1, 61010-2-032/033 
and electromagnetic radiation protection EN61326-1 safety standards, 
and conforms to CAT II 600V, CAT III 300V, double insulation and 
pollution grade II. 
 Note: In case the meter is not used in accordance with the 
operating instructions, the protection provided by the meter may be 
weakened or lost. 
1.Before use, please check if there is any item which is damaged or 
 behaving abnormally. If any abnormal item (such as bare test lead, 
 damaged meter casing, broken LCD, etc.) is found, or if the meter 
 is considered to be malfunctioning, please do not use the meter. 
2.Do not use the meter if the rear cover or the battery cover is not 
 covered up, or it will pose a shock hazard!
3.When using the meter, keep fingers behind the finger guards of the 
 test leads, and do not touch exposed wires, connectors, unused 
 inputs, or circuits being measured to prevent electric shock. 
4.The function switch should be placed in the correct position before 
 measurement. It is forbidden to change the position during 
 measurement to avoid damage to the meter!
5.Do not apply voltage over 600V between any meter terminal and 
 earth ground to prevent electric shock or damage to the meter.
6. Be cautious when the measured voltage is higher than 60V (DC) 
 or 30Vrms (AC) to avoid electric shock!
7.Never input voltage or current which exceeds the specified limit. If 
 the range of the measured value is unknown, the maximum range 
 should be selected. 
8.Before measuring the resistance, diode and continuity online, switch 
 off the power supply of the circuit, and fully discharge all capacitors 
 to avoid inaccurate measurement.
Description
Caution, possibility of electric shock
Alternating current
Direct current
Equipment protected throughout by DOUBLE 
INSULATION or REINFORCED INSULATION
Earth (ground) TERMINAL
Warning or Caution
VI. General Specifications
1. Max display: 4099 (UT201+/UT202+), 6099 (UT202A+)
2. Polarity display: Auto
3. Overload display: “OL” or “-OL” 
4. Low battery indication: The “ ” symbol is displayed.
5. Low battery shutdown prompt: The “Lo.bt” interface appears on the LCD 
 and lasts for about 10s, the buzzer beeps three times, and the meter 
 automatically shuts down.
6. Test position error: If the source under test is not placed at the center of 
 the clamp jaws when measuring current, ±1.0% additional error in reading 
 will be produced. 
7. Drop protection: 1m
8. The maximum size of jaw opening: 28mm in diameter 
9. Battery: AAA battery 1.5V×2
10.Auto power off: If there is no operation of the function switch or any 
 button for 15 minutes, the meter will automatically power off. This function 
 can be turned off as needed.
11.Dimensions: 215mm×63.5mm×36mm
12.Weight: About 248g (including batteries)
13.Altitude: 2000m
14.Operating temperature and humidity: 0°C~30°C ( 80%RH), 30°C~40°C ≤
 ( 75%RH), 40°C~50°C ( 45%RH)≤ ≤
15.Storage temperature and humidity: -20°C~60°C ( 80%RH)≤
16.Electromagnetic compatibility:
 RF=1V/m, overall accuracy = specified accuracy + 5% of range
 RF>1V/m, no specified calculation
VII. External Structure (Picture 1)
1. NCV sensing end 
2. Clamp jaws
3. Hand guard 
4. LED indicator
5. Jaw opening trigger
6. Function switch
7. LCD display
8. Function buttons
9. Positive (+) input jack
10.COM (negative -) input jack 
VIII. Button Description
1.SELECT Button
In the composite function position, press this button to switch between the 
corresponding measurement functions; in the AC/DC/Hz position (UT202+/
UT202A+), short press this button to switch between the AC and DC 
functions, and long press (about 2s) this button to enter/exit the Hz 
measurement function.
In the NCV/LIVE position (UT202A+ only), short press this button to switch 
between the EFHI and EFLo ranges, and long press (about 2s) this button 
to enter/exit the LIVE measurement function.
2.HOLD/BACKLIGHT Button
Short press this button to enter/exit the data hold mode, and long press 
(about 2s) this button to turn on/off the backlight (the backlight will 
automatically turn off after 60s).
3.MAX/MIN Button
Short press this button to enter the maximum/minimum measurement mode 
and long press this button to exit (only valid for AC/DC voltage, AC current, 
resistance and temperature measurement).
4.REL Button (UT202+/UT202A+)
In the capacitance and voltage positions, press this button to store the 
current reading as a reference for future readings. When the LCD display 
value is reset to zero, the stored reading will be subtracted from the future 
readings. Press this button again to exit the relative value mode.
2.AC/DC Voltage and Voltage Frequency Measurement (Picture 3)
1) Insert the red test lead into the “ ” jack, black into 
 the “ COM ” jack.
2) Turn the function switch to the AC/DC voltage position, and connect 
 the test leads with the measured load or power supply in parallel.
3.Resistance Measurement (Picture 4)
1) Insert the red test lead into the “ ” jack, black into 
 the “  ” jack.COM 
2) Turn the function switch to the “Ω” position, press the SELECT 
 button to select resistance measurement, and connect the test 
 leads with both ends of the measured resistance in parallel.
Capacitance
Continuity
Diode
Resistance
Note:
• If the measured resistor is open or the resistance exceeds the 
 maximum range, the LCD will display “OL”.
• Before measuring the resistance online, switch off the power supply 
 of the circuit, and fully discharge all capacitors to avoid inaccurate 
 measurement. 
• If the resistance is not less than 0.5Ω when the test leads are 
 short-circuited, please check the test leads for looseness or other 
 abnormalities.
• Do not input voltage higher than 30V to avoid personal injury.
4.Continuity Test (Picture 4)
1) Insert the red test lead into the “ ” jack, black into 
 the “ ” jack.
2) Turn the function switch to the “ ” position, press the SELECT 
 button to select continuity measurement, and connect the test leads 
 with both ends of the measured load in parallel.
3) Measured resistance <10Ω: The circuit is in good conduction status; 
 the buzzer beeps continuously. Measured resistance >31Ω: The 
 buzzer makes no sound.
Note:
• Before measuring the continuity online, switch off the power supply 
 of the circuit, and fully discharge all capacitors.
• Do not input voltage higher than 30V to avoid personal injury.
5. Diode Test (Picture 4)
1) Insert the red test lead into the “ ” jack, black into 
 the “ COM ” jack. The polarity of the red test lead is “+” and that 
  the black test lead is “-”.of 
2) Turn the function switch to the “ ” position, press the SELECT 
 button to select diode measurement, and connect the test leads 
 with the positive and negative poles of the measured diode.
3) 0.08V ≤ reading <1.2V: The buzzer makes one beep indicating 
 the normality of the diode. Reading <0.08V: The buzzer beeps 
 continuously indicating the damage of the diode. For the silicon 
 PN junction, the normal value is generally about 500~800 mV.
9.When the “ ” symbol appears on the LCD, please replace the batteries 
 in time to ensure measurement accuracy. If the meter is not in use for a 
 long time, please remove the batteries.
10.Do not change the internal circuit of the meter to avoid damage to the 
 meter and user!
11.Do not use or store the meter in high temperature, high humidity, flammable, 
 explosive or strong magnetic field environments.
12.Clean the meter casing with a soft cloth and mild detergent. Do not use 
 abrasives or solvents!
V. Electrical Symbols
IX. Operating Instructions
1.AC Current/Current Frequency Measurement (Picture 2)
1) Select the AC current range (4A/6A, 40A/60A or 400A/600A) 
2) Press the trigger to open the clamp jaws, and fully enclose one conductor.
3) Only one conductor can be measured at a time, otherwise the 
 measurement reading will be wrong.
AC current 
measurement
Current frequency 
measurement
Picture 2
Note:
• The current measurement must be taken within 0°C~40°C. Do not 
 suddenly release the trigger, as the impact will change the reading 
 for a short time. 
• To ensure measurement accuracy, center the conductor in the jaws.
 Otherwise, ±1.0% additional error in reading will be produced. 
• When the measured current is ≥400A (UT201+/UT202+)/ 600A ≥
 (UT202A+), the meter will automatically sound an alarm and the 
 high voltage alarm prompt “ ” will automatically flash.
• If the LCD displays “OL”, it indicates that the current is over range 
 and there is a danger of damage to the meter. 
Note:
• If the diode is open or its polarity is reversed, the LCD will display
 “OL”.
• Before measuring the diode online, switch off the power supply of 
 the circuit, and fully discharge all capacitors.
• Do not input voltage higher than 30V to avoid personal injury.
Red Black
Red Black
Picture 3
Picture 4
Picture 1
Symbol
   Note:
• Do not input voltage above 600V. Although it is possible to measure 
 higher voltage, it may damage the meter.
• Be cautious to avoid electric shock when measuring high voltage.
• When the measured voltage is ≥30V (AC) or ≥60V (DC), the LCD 
 will display the high voltage alarm prompt “