Specifications
24
high temperature, explosives, and strong 
magnetic field. 
B. Replacing the Fuses (see figure 11) 
Warning 
To avoid electrical shock or arc blast, which would 
cause personal injury or damage to the Meter, use 
specified fuses ONLY in accordance with the 
following procedure. 
To replace the Meter’s fuse: 
1.  Turn the Meter off. 
2.  Remove the outer holster from the Meter. 
3.  Remove all connections from the Meter’s 
terminals.
4.  Remove the 3 screws from the case bottom, and 
separate the case top from the case bottom. 
5.  Remove the fuse by gently prying one end loose, 
and remove the fuse from its bracket. 
6.  Install ONLY replacement fuses with the identical 
type and specification as follows and make sure 
the fuse is fixed firmly in the bracket. 
Fuse 1: 10A, 250V, fast type, ij5x20 mm. 
Fuse 2:    500mA, 250V, fast type, ij5x20 mm. 
7.  Rejoin the case bottom and case top, and 
reinstall the 3 screws. 
Replacement of the fuses is seldom required. Blowing 
of a fuse almost always results from improper 
operation.