User's Manual

RESETTING THE SCANNER
If the scanner’s display locks up or stops operating properly, you might need to reset the scanner.
Caution: This procedure clears all the information you have stored in the scanner. Before you reset the scanner,
try turning it off and on to see if it begins working properly. Reset the scanner only when you are sure it is
not working properly.
1. Turn off the scanner.
2. While holding down 2, 9 and HOLD, turn on the scanner. CLEAr flashes for about 5 seconds as the
scanner
clears its memory.
Note: Do not turn off the scanner again until CLEAr stops flashing. Otherwise, the scanner might not clear its
memory properly.
Follow these steps to restore the 150 preprogrammed frequencies stored in the private bank.
1. Make sure your scanner is turned off.
2. While holding down 3 and E/PGM, turn on the scanner. After several seconds, the scanner restores the
frequencies.
Specifications
Frequency Coverage: ...................
29–54 MHz (in 5 kHz steps)
108–136.9875 MHz (in 12.5 kHz steps)
137–174 MHz (in 5 kHz steps)
179.7500-215.7500 (in 6MHz steps)
216–224.995 MHz (in 5 kHz steps)
225-399.9875 (in 12.5kHz steps)
400–512 MHz (in 6.25 kHz steps)
806.0000–823.9875 MHz (in 12.5 kHz steps)
849.0125–868.9875 MHz (in 12.5 kHz steps)
894.0125–956.0000 MHz (in 12.5 kHz steps)
1240.0000–1300.0000 MHz (in 12.5 kHz steps)
Number of Banks ................................................................... 10
Sensitivity (AM/FM/WFM):
FM ............................................... 20 dB S/N at 3 kHz deviation)
29–54 MHz..................................................... 0.4 µV
137–174 MHz ............................................... 0.5 µV
216–225 MHz ............................................... 0.5 µV
400–512 MHz ............................................... 0.4 µV
806–956 MHz ............................................... 0.6 µV
1240–1300 MHz ........................................... 1.0 µV
AM ............................................ 20 dB S/N at 60% modulation)
108–136.9875 MHz ...................................... 1.6 µV
225–400 MHz ............................................... 1.5 µV
WFM ............................................... 20 dB S/N at 22.5 kHz deviation)
179.750–215.750 MHz ................................. 2.0 µV
Spurious Rejection (at 40.84 MHz) .................................. 50 dB