BAND SCOPE MODE
The Band Scope feature lets you have the scanner provide a visual representation of radio activity
in a frequency band. The screen is arranged with the frequencies increasing in value from left-to-
right, and a signal strength meter for signals. Band Scope Mode searches a frequency range and
displays the signal level in real time. You can set the center frequency and span of the frequency
range. In Hold Mode, you can monitor the displayed frequency.
The scanner rapidly sweeps between the endpoints of the selected frequency range and updates
each bar segment with the relative signal strength in each pass. You can use the band scope in
normal mode (the bars are all updated with the most recent signal strength) or ‘Max Hold Mode’
(the bars update only if there is a stronger signal than one previously stored for the current
position).
This feature allows you to get a “picture” of spectrum activity across the selected range, identify
intermittently active frequencies, check antenna performance, check coax quality, verify coverage
areas, and identify interference.