Owner`s manual

39
UNIDEN UH8080NB UHF CB Transceiver
Operation - Special Features
Lead-in Delay Programming
1. Power Off the UH8080NB.
2. Press and hold [POWER] and [MENU]. The SELCALL Settings Menu will display (no
tone will sound).
3. Press [MENU] repeatedly to select the Lead-in Delay setting - which is indicated on
the display as Ld.
4. Press [SQL]toeditthesetting.Thecurrentsettingashes.
5. Press
/ toselectthedesiredLead-indelayperiodfrom500ms,1000ms,
2000ms,3000msor4000ms.
6. Press [SQL] to exit the setting.
7. Press and hold [ENTER],tosaveandexitprogrammingmode.
Lead-in Tone
TheLead-inTone,whenprogrammed,‘rides’ontheLead-inDelay.
Hence,whentransmittingaSelcallID,acontinuoustonewillbeheardforthedurationof
the Lead-in Delay. The main purpose of the Lead-in Tone is to increase the probability of
contact between your unit and another radio when TSQ Scanning.
1. Power Off the UH8080NB.
2. Press and hold [POWER] and [MENU]. The SELCALL Settings Menu will display (no
tone will sound).
3. Press [MENU] repeatedly to select the Lead-in Tone setting - which is indicated on the
display as LT.
4. Press [SQL]toeditthesetting.Thecurrentsettingashes.
5. Press
/ to select the desired Lead-in Tone.
NOTE
•IfyouwanttoremovetheLead-inTonechoosethespace[_]Bar.
6. Press [SQL] to exit the setting.
7. Press and hold [ENTER],tosaveandexitprogrammingmode.