User's Manual

V1.4
Professional Computer Technology Limited
Confidential
4
5. Receiver
Initialization: (System to Module)
Address
Name Type No.of Byte Description
1 Start byte
1
0XAA
2 TX/RX 1 0X01 (TX: 0X00, RX: 0X01)
3
Test Mode 1
Normal: 0X00, Test Mode: 0x01. No frequency
hopping in test mode.
4-31 Data 28 TBD, All data equal to 0X00
32 CheckSum 1 Checksum
Data: (Module to System)
Address
Name Type No.of Byte Description
1 Start Byte
1 0X88 Data Transmitted success, No Data received.
0X8A Data Transmitted success, Data Received.
0X80 UART Transmitted failed
0X81 Data Transmitted failed
2 Machine ID 1 Machine ID of RX module(ID: 1 to 64)
3-30 Data 29 Customer can define the data format
32 CheckSum 1 Checksum of 31 bytes data
Data: (System to Module)
Address
Name Type No.of Byte Description
1 Start Byte
1 Start byte equal to 0x55
2 Machine ID 1 Machine ID of RX module(ID: 1 to 64)
3-30 Data 29 Customer can define the data format
32 CheckSum 1 Checksum of 31 bytes data