PIN Pad 791 Programmer’s Manual (PCI POS-A) UDN PM0103-U Rev. 06
Section 6 – Contact EMV Level 2 transaction messages 2015-04-20
Page116
Uniform Industrial Corp. Proprietary and Confidential Total 342 pages
Ref. 4 Packet command flow for transaction with online and Issuer Script command
Processing
HOST Direction PIN pad
T11 (Application Select )
T12 (Application Select Response)
T15 (Start Transaction)
T16 (Start Transaction Response)
[Result] = ‘A1’
T27 (Get online data from PIN pad)
T28 (Online authorization data response)
Go Online
T19 (Send Issuer Script command)
(if many commands)
T20 (Send Issuer Script command
Response, continued)
T1D (Send necessary online response
data to PIN pad.)
T1E
T17 (Send Online Authorized Code)
T16 (Start Transaction Response)
[Result] = ‘Y3’ or ‘Y4’ or ‘Z3’ or ‘Z4’
T21 (Get Transaction Result’s Data)
T22 (Get Transaction Result’s Data
Response)
Ref. 5 Packet command flow for first EMV application is blocked
HOST Direction PIN Pad
T11 (Application Select )
T12 (Application Select Response)
T15 (Start Transaction)
T16 (Start Transaction Response)
[Result] = ‘A4’
T13 (Application Select Next)
T12 (Application Select Response)