Message T76 Revocation List Setup Response
Format: <STX>T76[Res][Reason][Err Msg]<ETX>[LRC]
Message length: Variable.
Usage: The response message of command T75.
Message element:
Field Length Value and description
<STX> 1 <02>
T76 3 Message ID
[Res] 1 ‘0’: Ok,
‘1’: Fail
[Reason] 1 <Optional, if Res = ‘1’>
‘1’: Fatal error
‘2’: Invalid Data format
‘3’: Revocation list is full
‘4’: The added info exists
[Err Message] 8 Optional, if Reason = ‘1’, Hex decimal string
<ETX> 1 <03>
[LRC] 1 Checksum
Message flow: Please refer to message T75.