User's Manual

PIN Pad 791 Programmer’s Manual (PCI POS-A) UDN PM0103-U Rev. 06
Section 7 – Contactless EMV Level 2 transaction messages 2015-04-20
Page152
Uniform Industrial Corp. Proprietary and Confidential Total 342 pages
Message T78 Exception List Setup Response
Format: <STX>T78[Resp][Reason][Err Msg]<ETX>[LRC]
Message length: Variable.
Usage: The response message of command T77.
Message element:
Field Length Value and description
<STX> 1 <02>
T78 3 Message ID
[Resp] 1 ‘0’: Ok,
‘1’: Fail
[Reason] 1 Option if [Resp] is ‘1’,
‘1’: Fatal Error
‘2’: Format Error
‘3’: Exception List is full
‘4’: PAN exists
[Err Message] 8 Optional, if Reason = ‘1’,
Hex String
<ETX> 1 <03>
[LRC] 1 Checksum
Message flow: Please refer to message T77