User's Manual

PIN Pad 791 Programmer’s Manual (PCI POS-A) UDN PM0103-U Rev. 06
Section 3 –PP791 Setup & Diagnostic Menu 2015-04-20
Page20
Uniform Industrial Corp. Proprietary and Confidential Total 342 pages
Section 3 PP791 Setup & Diagnostic Menu
Call up Diagnostic Menu
Press function key [CLR] + [3] (quickly press ‘3’ after [CLR] released) of PP791 will call up diagnostic
menu when PP791 in idle state. The default 2 passwords for diagnostic menu are “87806799” (both
passwords)
DISPLAY ACTION
(Idle prompt) Power on.
Press [CLR]+[3]
Password 1?
Input first setup password and press [ENTER]
Password 2?
Input second setup password and press [ENTER]
HW Tests
Display Info
Setup COM Port
Set LCD Backlight
Logo Setup
Update Password
Set Keypad Beep
Use [F1] ,[F3] to scroll up and down.
[F2] to go back.
[ENTER] to execute.
Diagnostic Menu 1: HW Tests
DISPLAY ACTION
Display Test
Display two pages of test pattern:
First page is turn on all pixels to check if there are any dot
damage. Press any key or wait 10 sec to continue.
Second page shows PP791 character sets. Press any key or wait
5 sec to leave.
Keypad Test
PP791 will echo user’s input key at line 2.
Press [CAN] to leave this test.
MSR Test
PP791 will show MSR TEST –SWIPEon LCD and wait for
user to swipe any magnetic stripe card. After card swiped, a
submenu will displayed to let user check track 1,2,3
independently.
ICC Test
Insert an EMV Lv1 compatible smart card into primary card
slot, and then select this function. PP791 will display its ATR
string on LCD for check.