User's Manual

PIN Pad 791 Programmer’s Manual (PCI POS-A) UDN PM0103-U Rev. 06
Section 9 – Online transaction messages with Master / Session keys 2015-04-20
Page223
Uniform Industrial Corp. Proprietary and Confidential Total 342 pages
Message Z50 String Entry Request
Format: <STX>Z50[echo flag][timeout][max entry]<ETX>[LRC]
Message length: Variable 10 to 12 bytes.
Usage: Request user to input string on keypad.
Then PP791 will wait for keypad input and store ASCII data into internal buffer. To
input English character on the keypad, press [F2] key to rotate the last character. For
example, press [1], [F2], [F2] will input a ‘Z’ character into PP791. The maximum
length of internal buffer is 49 characters.
User can use [CLR] to clear input buffer and input again, or [CAN] to cancel input.
Press ‘0’ and press [F2] will transform ‘0’ into period or white space.
Abort input: Issue message 72 to abort the operation.
Note: A Z2 or Z3 message with authenticated frame must be issued before Z50. Otherwise
PIN pad will refuse to execute.
Message element:
Field Length
Value and description
<STX> 1 <02>
Z50 3 Message ID
[echo flag] 1 ‘0’: echo input as ‘*’
‘1’: echo input as is
‘2’: do not echo
[timeout] 3 ASCII character from 1 to 255 to set the
timeout for each keypress, for example
“010” means 10 seconds timeout after
the last keypress.
[max entry] 1 or 2 (optional) Maximum entry count.
Range from 00 to 49 (or 0 to 49)
<ETX> 1 <03>
[LRC] 1 Checksum