User's Manual

PIN Pad 791 Programmer’s Manual (PCI POS-A) UDN PM0103-U Rev. 06
Section 11 – ICC / SAM / Magnetic stripe card manipulating messages 2015-04-20
Page276
Uniform Industrial Corp. Proprietary and Confidential Total 342 pages
Message I17 SAM slot R-APDU
Format: <STX>I17[R-APDU]<ETX>[LRC]
Message length: Variable 10 to 530 bytes.
Usage: After SAM card processes the Command-APDU, it puts the result as the
Response-APDU. PP791 packs the Response-APDU into this message packet and
sends to host.
Message element:
Field Length
Value and description
<STX> 1 <02>
I17 3 Message ID
[R-APDU] 4.. 524
Smart card response APDU
Format: hexadecimal string.
<ETX> 1 <03>
[LRC] 1 Checksum
Message flow: Please refer to message I16.