For a set of error cases, specific error codes are defined. These error codes are shown in brack-
ets on the display, following a general error note. Example: „No Telephony possible (LP1)“.
http://wiki.unify.com/wiki/_SIP_FAQ#Error_codes
Problem Description Error code
Network Problem No network connection LI1
Not Initialised Waiting for data I1
Unable to use LAN 802.1x error LX1
Unable to use LAN Physical connection missing LP1
Unable to Register Server timeout RT2
Unable to Register Server failed RF2
Unable to Register Authentication failed RA2
Unable to Register No number configured RN2
Unable to Register No server configured RS2
Unable to Register No registrar configured RG2
Unable to Register No DNS domain configured RD2
Unable to Register Rejected by server RR2
Unable to Register No phone IP address set RI2
Survivability Backup route active B8
Survivability Backup not configured RS8
Survivability Backup timeout RT8
Survivability Backup authentication failed RA8
Cloud-Deployment
abandoned by user
Cloud-Deployment abandoned by user
Occurs when the pin prompt is dismissed
AU
Tabelle 5-1 Troubleshooting Error Codes
>
A special “fast-busy” tone (also called congestion tone) is played if a temporary net-
work problem causes a user-initiated call action to fail. Typical call actions: making
an outgoing call; picking up a call from Manual Hold; or Group pickup. Phone users
and mobile users logged on to the phone. The special tone is triggered if one of the
following SIP response codes is received from the server:
606, 408, or 503.