Physical Implementation
The physical implementation of the RF transmission line must conform to the following
guidelines:
Coaxial Cable: A coaxial of varying length may be used providing the impedance
measures 50 +/- 2 ohms and is non-radiating. Best practice RF engineering suggests
the cable should be kept to the minimum length required to satisfy the application.
Excessive cable and interconnect loss may adversely effect the effective transmission
and reception range of the end product.
Emissions Compliance Testing
Notwithstanding the Modular Approval for the Radio Device with associated interconnect and
antennae, the end product configuration must meet digital emissions compliance and must be
tested in accordance with Industry Canada RSS-210 (Low Power License-Exempt Radio
communication Devices) requirements confirming radiated emissions are within specified
limits.
Applicable sections include:
Part 15 Section 15.109 Sub-paragraph A, Class B Radiated Emission Limits
These emissions tests can be conducted by the manufacturer or by contacting an approved
test facility equipped and certified accordingly. The results of these emissions tests are not
required to be submitted to the FCC or Unigen, but should be kept on file by the OEM.
Note:
Industry Canada generally follows the guidelines of the FCC for emissions level requirements.
FCC end-product compliance certification results may be used to satisfy Industry Canada
requirements. Please consult the Industry Canada, RSS 210 specifications to confirm inter-
agency compliance. If comparable FCC testing has not been performed or if the specifications
are not cross compliant, RSS 210 testing will be required.
Product Labeling Requirements
Industry Canada product labeling requirements stipulate specific text be placed on the device
containing the UGWR2US module. The product must include the following text and must be
located on the exterior of the OEM’s product. This same information must be included in the
product user manual.
“This product contains Unigen WirelessUSB module
Canadian Cert No IC: 5125A-UGWR2US”