User's Manual

22
Is the sensitivity -120dBm?
No
Check XFL301/302 and other
devices around Q303.
Yes
Send 21.4 MHz to Pin No. 6 of
U101. (SSG)
Check T-TAL filter and other
parts of XFL301/302.
Yes
Is 21.4MHz sensitivity around
–98dBm?
Yes
Is the bias of each end of
Q303 normal? (VTVM)
No
Check the IFIC Q303
amplifier, RX 5V,
power supply, and parts.
No
No
Replace the IF U101.
Does the sub-oscillator of the
secondary station (20.945MHz)
in the X301 oscillate?
(Scope, Counter)
No
Is the voltage at Pin 4 of the
IF U101 normal? (VTVM)
Yes Yes
Check voltages at each pin of
the IF U101. (VTVM)
Replace X-TAL and other parts
of the sub-oscillator of the
secondary station in X301.
Yes
Is the voltage at each pin
normal? (VTVM)
Yes
Check connection parts of the
IF U101.
No
Check IF U101 and parts,
and replace IF U101 if needed.