3.5.3. Door Setting
Select [F3~] → [3.Option] → [3.Doorlock] on the main screen, and the following screen will
appear.
3.5.3.1. Door Open Time Setting
Default Setting: ‘03’(Unit: Second)
This option is to specify the time when after authentication through the terminal, the door is
opened and then closed. Strike type means the time when if opening the door after
authentication, the door is automatically locked again. In the case of Dead Bolt type and Auto
Door, the door will work regardless of the value.
If the mode is set to ‘00’, it is impossible to control the door. '00' must be set only when the
door is not connected to Lock.
After selecting the set value, press [F4] button to move to the next setting.
3.5.3.2. Door Open Alarm Setting
Default Setting: ‘00’
This option allows the terminal to check the time when the door is open. If the door is open
over the set time (minimum 5 seconds to maximum 30 seconds), an alarm occurs. When the
time is set to ‘00’, no alarm occurs. Even if the time is set to 01~04, an alarm starts to sound
after the lapse of at least 5 seconds.
The door must be closed within the set time. But, it may not be closed due to unforeseen
circumstances. The alarm allows users to check the cause that the door is unclosed and take
any action so that the door can be closed normally.