3.7.3. Monitor Input Port Setting
This option acts to connect the sensor to the terminal input port, and send a notice message to the
server when the status is changed.
Select [F3~]→[5.Ext Function]→[3.Monitor] on the main screen, and the following screen will
appear.
(Caution) DM2 is a currently unused spare port. Before using the relevant function, check the required
ports and install.
3.7.3.1. Monitor 1 Input Port Setting
Set when connecting an external contact to DM0. (When
using a motor lock, set to 1 or 2.)
Default Setting: ‘0.None’
- ‘0.None’: When nothing is connected
- ‘1.NO’ or ‘2.NC’: When the open door status monitoring pin is connected
- ‘3.Fire NO’ or ‘4.Fire NC’: When the fire detection sensor is connected
- ‘5.Panic NO’ or ‘6.Panic NC’: When the panic situation detection sensor is connected
- ‘7.EMC NO’ or ‘8.EMC NC’: When the emergency detection sensor is connected
- ‘9.Ctrler Out’: When the authentication result is sent to the external controller
(Connect the REDled of controller to DM0 or DM1 through the board has the TR. Set the
relevant pin to ‘9.Ctrler Out’. WiegandOut must be set.)
Press [ENT] button to move to the next setting.
3.7.3.2. Monitor 2 Input Port Setting
Set when connecting an external contact to DM1. (When
using a motor lock, set to 1 or 2.)
Default Setting: ‘0.None’
- ‘0.None’: When nothing is connected
- ‘1.NO’ or ‘2.NC’: When the open door status monitoring pin is connected