- ‘3.Fire NO’ or ‘4.Fire NC’: When the fire detection sensor is connected
- ‘5.Panic NO’ or ‘6.Panic NC’: When the panic situation detection sensor is connected
- ‘7.EMC NO’ or ‘8.EMC NC’: When the emergency detection sensor is connected
- ‘9.Ctrler Out’: When the authentication result is sent to the external controller
(Connect the REDled of controller to DM0 or DM1 through the board has the TR. Set the
relevant pin to ‘9.Ctrler Out’. WiegandOut must be set.)
After selecting the set value, press [ENT] button, and the screen will go to the upper menu.
3.7.4. Duress FP Setting
Select [F3~]→[5.Ext Function]→[4.Duress FP] on the main screen, and the following screen will
appear.
3.7.4.1 Duress FP
This function allows users to use an alarm when the duress fingerprint is entered.
Set whether to use the duress fingerprint alarm.
Default Setting: ‘2.No’
The default setting is '2.No'. When it is set to ‘1.Yes’, if the pre-registered fingerprint is
authenticated, the ‘L2’ Pin will output the DC12V. If any emergency detection device such as a
siren is connected to this Pin, it will operate.
If <Duress FP> is set to ‘1.Yes’, the menu for setting the time corresponding to 12V will appear.
Default Setting: ‘03’ (Unit: Second)
To modify, Press [←][→] buttons to move to the desired position, and press [↑][↓] buttons to
change the existing value.
After selecting the set value, press [ENT] button, and the screen will go to the upper menu.