User's Manual

AC-2100 Plus 사용자 이드 63
UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro,
Songpa-gu, Seoul, 05836, Republic of Korea
TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr
http://www.unioncomm.co.kr
Default Setting: ‘1’
This option is used only when the terminal is equipped with a separate controller operated by
Wiegand input. After authentication, the following types of data are sent to the Wiegand port of
the terminal.
1.None
General case. The Wiegand Out port is not used.
2.26bit
“Sitecode [1 byte] + User ID [2 bytes]” are transferred. User ID should be set
to the 4-digit or less number.
Example) SiteCode:045, UID:6543
→ 1 00101101 0001 1001 10001111 0
3.34bit
“Sitecode [1 byte] + User ID [3 bytes]” are transferred. User ID should be set
to the 7-digit or less number.
However, if User ID is 8 digits, Sitecode is ignored and only “User ID [4
bytes]” is transferred.
Example) SiteCode:001, UID:123456
→ 0 00000001 00000001 11100010 01000000 0
4.Custom
This is the user-defined setting that is available only in the server. Only
checking is possible in the terminal.
This option is unrelated to use the Wiegand type card reader. If the mode is set to ‘2’ or ‘3’,
the following site code is set.
Default Setting: ‘000’
This option is available only when Wiegand Out is set to ‘2’ or ‘3’. The site code to send to
Wiegand port including User ID is set to the value of 0~255.
After selecting the set value, press [F4] button, and the screen will go to the upper menu.
3.8.4.1. Bypass Setting