3.5.3. Door Setting
Select [F3~] → [3.Option] → [3.Doorlock] on the main screen, and the following screen will
appear.
3.5.3.1. Lock Type Setting
Set to ‘1’ when the terminal is connected to the strike type
or automatic door, and ‘2’ when it is connected to the
motor lock.
Default Setting: ‘1.Strike’
Set to ‘1’ even if the door lock is not connected.
Set to ‘3’ if the lamp for displaying authentication success/failure is installed the lock port.
Press [ENT] button to move to the next setting.
3.5.3.2. Door Open Time Setting
Default Setting: ‘03’(Unit: Second)
This option is to specify the time when after authentication through the terminal, the door is
opened and then closed. Strike type means the time when if opening the door after
authentication, the door is automatically locked again. In the case of Dead Bolt type and Auto
Door, the door will work regardless of the value.
If the mode is set to 00’, it is impossible to control the door. '00' must be set only when the
door is not connected to Lock.
After selecting the set value, press [F4] button to move to the next setting.