3.7.4. Duress FP Setting
Select [F3~]→[5.Ext Function]→[4.Duress FP] on the main screen, and the following screen will
appear.
3.7.4.1 Duress FP
This function allows users to use an alarm when the duress fingerprint is entered.
Set whether to use the duress fingerprint alarm.
Default Setting: ‘2.No’
The default setting is '2.No'. When it is set to ‘1.Yes’, if the pre-registered fingerprint is
authenticated, the voltage of 12V will flow into ‘L2’ Pin. If any emergency detection device
such as a siren is connected to this Pin, it will operate.
If <Duress FP> is set to ‘1.Yes’, the menu for setting the time corresponding to 2V will appear.
Default Setting: ‘03’ (Unit: Second)
To modify, Press [←][→] buttons to move to the desired position, and press [↑][↓] buttons to
change the existing value.
After selecting the set value, press [ENT] button, and the screen will go to the upper menu.