User's Manual

AC-5000 / 5100 User Guide 56
UNIONCOMMUNITY Co., Ltd. / 12F, Daemyung Valeon, 127, Beobwon-ro,
Songpa-gu, Seoul, 05836, Republic of Korea
TEL: +82-2-6488-3000 / FAX: +82-2-6488-3100 E-Mail :sales@unioncomm.co.kr
http://www.unioncomm.co.kr
2.
Hexadecimal
number
0801161DD6
10-digit hexadecimal number
3. Decimal
number
0018226646
Last 4byte to be expressed in a 10-digit decimal
number (01161DD6h)
4. Decimal
number 35
02207638
Same as ‘1. Default’
5. Hexa_1
161DD6
Displays last 3bytes as the 6-digit hexadecimal
number.
SC card example: Card Number (4byte): 52h 9Dh 06h E3h
Card Format
Card number
Method of Expression
1. Default
529D06E3
Expressed as an 8-digit hexadecimal number
2.
Hexadecimal
number
E3069D52
Expressed as an 8-digit hexadecimal number
changing the order of byte
3. Decimal
number
1386022627
Hexadecimal number 529D06E3 to be expressed as a
10-digit decimal number
4. Decimal
number 35
3808861522
Hexadecimal number E3069D52 to be expressed as a
10-digit decimal number
5. Hexa_1
069D52
Only the first 3 bytes are placed upside down.
The user can exit to the parent menu using the [ENT~] key to apply the changed values. Use
the [F4 ()] key to cancel input during setting.
3.7.6. External Device
Select [ENT~] ([5. Terminal] [6. External Device]) in the initial screen , and the following
screen appears.
Connector Settings shown as below
Initial setting: Identical with the screen on the
left.