MiKey AC1100 User Guide Version eng-1.06 Copyright 2000 By Union Community Co., LTD.
MiKey AC1100 User guide Version Date Description Firmware Version 1.00 2016-04-24 Initial Release V1.00.000-010 1.01 1.02/3 2016-05-10 2016-05-31 Update Update Images V1.00.000-013 Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 3 < Glossary> Admin, Administrator - A user who can enter into the terminal menu mode, he/she can register/modify/delete terminal users and change the operating environment by changing settings. - If there is no administrator for a terminal, anyone can change the settings. In this regard, it is recommended to register at least one administrator.
MiKey AC1100 User guide Contents .................................................................................................... 2 < Glossary> ............................................................................................................... 3 Contents ................................................................................................................... 4 1. Before use .......................................................................................
MiKey AC1100 User guide 5 3.7.3. Terminal Input ............................................................................................... 58 3.7.4. Terminal Lock ............................................................................................... 60 3.7.5. Terminal Wiegand ......................................................................................... 62 3.7.6. Terminal External .......................................................................................... 63 3.8.
MiKey AC1100 User guide 1. Before use 1.1. Safety precautions Warning Handling with wet hands or allowing liquid to flow into it is prohibited. -> It may cause an electric shock or damage. Do not place a fire source near the terminal. -> It may cause a fire. Do not disassemble, repair, or modify the terminal at discretion. -> It may cause an electric shock, fire or damage. Keep out of reach of children. -> It may cause an accident or damage.
MiKey AC1100 User guide 1.2. Specific names of the terminal Camera Day-Light Sensor Camera Flash Microphone Touch LCD Card input Speaker Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 1.3. Normal Window Display Status Icons See below Status Touch Admin button Present time ID input button Entrance mode selection button (Indication of the state of the entrance) Extended Key Mode BackGround Image 1.3.1.
MiKey AC1100 User guide WiFi Connection State : WiFi Dongle Connected to device – not connected to network : WiFi Dongle Connected and successfully connected to AP Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 10 1.3.2. Window Messaging - Standard window - Screen Saver window Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 11 All Function Keys disabled - No Status Text/ Status Text Background - No Extended Key VoiP Function VoIP enabled, not registered. VoIP enabled, registered on iPBX network Select Green Icon to access VoIP call menu. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 12 Touch the ‘status touch area’ along the top of the display to see detail status information. See 1.3 Main window display. This will appear for 10 seconds. Top pop up is a ‘custom user message’.In UNIS user management you can make a custom message for every user during the users authentication period. If camera setting for Display Current Picture or Display User picture is set and registered card is used. Picture will be displayed on the top. See Section 3.8.
MiKey AC1100 User guide 13 - When authorization is failed. - When unregistered user ID is entered. - When unregistered card is entered - Passback error when using anti-passback function.
MiKey AC1100 User guide 14 - Registration without authorization right or authorization attempt when the entrance is not permitted. - When the user is designated in the blacklist - When the terminal is set locked - When it is not the meal time when set in the meal personnel management. - When Bluetooth is connected with administrator Mobile App. Admin mode blocking.
MiKey AC1100 User guide 15 - Waiting for User ID Input If more than 2 function keys are enabled from the function key setting menu, in administrator mode, the button will appear on the main window. If this button is selected the extended function keys can be seen. Select the mode button - blue, or scroll down/up until you can see the mode you would like to select. Select back or the blue button mode. Timeout after 5 seconds of no activity.
MiKey AC1100 User guide 16 - Waiting for Password Input - Waiting for Card -When the terminal program is being upgraded (In this state, you should not turn off the terminal) Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 17 1.4. Voices in the operation Operation type When the authorization was successful When the authorization was failed. Voice You are authorized. Please try again. Waiting for Card Please enter your card ID Input Enter your ID 1.5.
MiKey AC1100 User guide 18 2. Product introduction 2.1. Product characteristics Multi-Modal product with card, password or mobile key authentication methods. Face Detection requires the current authenticating user to present their face during card, password or Mobile Key authentication. This requires a user to be in front of the card reader so the device can take a picture of the person who authenticated. Built in camera flash allows pictures and face detection during dark conditions.
MiKey AC1100 User guide 19 2.2. Product components 2.2.1. Stand-alone (entrance) DC12V Adapter Electric lock (Lock+, Lock-, Monitor) Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 20 2.2.2.
MiKey AC1100 User guide 21 2.3. Product specification Types SPEC CPU 1GHz Single Core CPU LCD 4.0 inch Touch LCD(480*800) MEMORY External USB support Camera Camera Flash Sensor User number Temperature / Humidity REMARK eMMc 8G Bytes Flash 512mb RAM Data backup / FW upgrade (USB port is service port.
MiKey AC1100 User guide 22 3. Environment setting 3.1. Checks before setting the environment 3.1.1. Entering the admin menu If you press the [ follows. ] icon at the main window, you can enter the administrator menu as You can enter the subdivision menu by selecting each button. Once in the administrator menu, if you need to soft reboot the device, touch the RED circled area, and then select the reboot icon in the middle, this will initiate a reboot.
MiKey AC1100 User guide 23 3.1.2. Administrator authorization If the administrator is registered, the following administrator authorization window appears first. ▶Administrator authorization If you enter the administrator ID, the administrator authorization is fulfilled along with the authorization method of the administrator such as card, or password. The administrator authorization only appears when the registered administrator exists.
MiKey AC1100 User guide 24 The server IP and network information will be displayed. You can now connect your card reader terminal directly to your PC. Setup your PC network card with the same Server IP and Gateway settings. After you successfully connect with UNIS you can change/delete the administer user as needed. Method #2 (USB port is service port.
MiKey AC1100 User guide 25 3.2. Menu composition 1.User management 1. 2. 3. 4. 5. Add Modify Delete Delete All View 2. Network Terminal IP address Static IP / DHCP ▶Terminal IP address ▶Subnet mask ▶Gateway DNS server 3.Application Server IP address ▶Server IP address ▶Port Terminal ID ▶Terminal ID Timeout ▶Server timeout 1. Application ▶Access ▶Attendance management ▶Meal management 1.
MiKey AC1100 User guide 26 4. System 1. System ▶User ID Length (2-9) ▶Authentication Type (Server/Terminal) (Terminal/Server) (Server Only) (Terminal Only) ▶Job Code enable/disable 2.Mobile ▶Enable Mobile Key ▶Mobile Key Name ▶Mobile Register Device 3. Face Detection ▶Card use ▶Mobile use ▶Password use ▶Detection Level Level 1 Level 2 5.Terminal setting 4. Date / time ▶Time Sync type ▶Display format ▶Date Setting ▶Time Setting 6. Database ▶ ▶ ▶ ▶ ▶ 1. Sound ▶Voice volume ▶Beep volume 2.
MiKey AC1100 User guide 27 6.Display 7.Terminal information 4. Lock setting ▶Lock1 ▶Lock2 ▶Lock1 ▶Lock2 5. Wiegand ▶Wiegand Site code Wiegand Output Wiegand Output Type Wiegand Input 6. External ▶Printer option ▶RS485 option 1. Theme ▶Main background screen Background cycle period (seconds) 2. Camera ▶Display option ▶Save option Save when authorization was successful Save when authorization was failed ▶ Flash option Disabled/Low/Medium/High Delay (milliseconds) 3. Language ▶Language 4.
MiKey AC1100 User guide 28 8. SD card 5. Log ▶Log information View Log 6. About ▶About Legal 1. Export ▶User data ▶Event log ▶System option ▶Export All ▶Picture data 2. Import ▶User data ▶System option 3. Other ▶Theme Background import Language file import ▶F/W upgrade 3.3. User management When you select the [User Settings] at the main menu, the following window appears. The number of all the users is shown at the top of screen including administrators.
MiKey AC1100 User guide 29 3.3.1. Adding User If you select [User Settings]->[Add] in the main menu, the following screen appears Input the user ID to be registered and select [OK] button. In this case, the ID which can be registered is shown on the screen automatically, so you can register conveniently. If you want to change ID, delete the previous value by selecting the input the new value. button and Click [Back] button to cancel and go back.
MiKey AC1100 User guide 30 You can register a card with [Card] button, a password with the [Password] button, and change the authentication type. The default user will be a standard user and not an administrator. ※ Users who are only registered as an administrator can change the settings of the terminal and can register/modify/delete the information of all the saved users. Take caution when registering an administrator. 3.3.1.1.
MiKey AC1100 User guide 31 3.3.1.5. Password registration Enter a password up to 8 digits in length. Once you are finished select the OK button, after a confirmation window will appear. !!! Enter the same digits to confirm your password is correct. Select the OK button to continue. If password is has not matched an error message will appear.
MiKey AC1100 User guide 32 3.3.1.6. Card registration Select the Card Icon to register a card. A popup message will appear waiting for you to scan your card. If successful the card number message will appear indicating successful. You can register up to 5 cards per user. If a same card number is attempted to register again, an error message will occur.
MiKey AC1100 User guide 33 3.3.1.8. Authorization method Select the Auth Type icon to change the authentication type of the user. If only card is registered, only a card icon will appear the same as password. If both are registered you can select a combination of both types using OR and AND. : card OR : password By selecting the BACK button the current selection is saved.
MiKey AC1100 User guide 34 : password only : card only 3.3.1.9. Save Select the [Save] button to save all user data when completed or select [Cancel] or [BACK] button to return, the user is not saved. LCD messages which can appear during the registration procedure. If user is not saved correctly this message will appear. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 35 3.3.2. Deleting User The following window appears if you select [User Settings]->[Delete] at the main menu. Input the user ID to be deleted and select [OK] button. Select [BACK] button to cancel and return. If you entered an invalid/unregistered ID, an error message will appear. If you entered a valid/registered ID a confirmation window will appear. Please note if connected to the server, the user is not deleted from the server.
MiKey AC1100 User guide 36 When unregistered ID was entered When user is deleted successfully. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 37 3.3.3. Modify User The following window appears if you select the [User Setting] -> [Modify] in the main menu. Input the user ID to be modified and Select [OK] button. Select [BACK] button to cancel and return. If you entered an invalid/unregistered ID, an error message will appear. . If you entered a valid/registered ID, the same menu as ‘add user’ will appear.
MiKey AC1100 User guide 38 3.3.4. Delete all Users If you select the [User Settings] ->[Delete all] in the main menu, the following window appears. Confirmation Window. Select YES to continue to delete all users Select NO to cancel the deletion. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 39 3.3.5. View If you select the [User management] -> [View] from the main menu, all the registered users can be viewed. User view area will show you a summary list of the users. User name, ID, Card number and authentication type will appear for each user. You can select a user for modification or deletion.
MiKey AC1100 User guide 40 The maximum amount of users displayed is 50. You can slide up or down in the box area (see above) to move up and down the list. If more than 50 users (maximum display) a forward icon will appear. If you select this, the next 50 users will display. Select 50 users. to move to the previous ▶ [ID]: Select the user ID area to move directly to the specific user’s modification window. See above picture ▶ [Del]: If you select this area, a checkbox will appear.
MiKey AC1100 User guide 41 3.4. Network Settings The networks settings area allows you to setup IP addresses, gateways, subnet mask, DHCP or static settings, Terminal ID Number or wireless settings. When selecting DHCP ensure that your network has a properly enabled DHCP server available. Also you should give time for the terminal to acquire the DHCP address; usually this can take from 1-60 seconds.
MiKey AC1100 User guide 42 the value, you should change the server program with the same value, so be cautious. ▶ [Terminal ID]: The terminal ID number uniquely identifies the terminal on the server program network. For every terminal on the server network you should program a different terminal number. This value should be 1-8 digits in length ▶ [Timeout]: The default timeout is 5 seconds.
MiKey AC1100 User guide 43 3.5. Application 3.5.1. Application mode If you select the [Application] in the main menu, the following window appears. In the application mode, you can select the [Access Control/ Attendance management/ Meal management] according to the purpose. 3.5.1.1. Modes Normal Access Mode It is the screen appearing when you select the Access. Select [OK] button to apply the changes, or select [BACK] button to cancel and return.
MiKey AC1100 User guide 44 Time and Attendance Select [OK] button to apply the changes, or select [BACK] button to cancel and return. Time schedules should be programmed when using this mode. Time and Attendance Application is for systems that require tracking of employee’s work time. If the system is setup for Time and Attendance, for authentication the user is required to touch the function key before entering their ID or Card.
MiKey AC1100 User guide 45 During the set time periods, the mode will change automatically to the time period setting. If a function key is pressed during the time period, the function key will change to the new mode, after 15 seconds the system will revert back to the current time setting mode. i.e , if Period mode = Leaving mode, Function key -> Enter mode is pressed, after 15 seconds the mode will change back to Leaving mode.
MiKey AC1100 User guide 46 ▶ Basic setting : Same with the window at the left side ▶F1-F4 Key Access button used to change the authorization mode such as attendance and leaving, and if you select the F1-F4 Key, the authorization mode is changed to the mode. Only the checked buttons will appear on the main window. Note: Only maximum 2 function keys will appear on the main window, any additional function keys will appear in the extended key window.
MiKey AC1100 User guide 47 3.6. System 3.6.1. System The following window appears if you select the [System] -> [System] in the main menu. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 48 ▶ User ID Length The user ID length can be 2 to 8 digits in length. The user ID length will be the length of the user ID required to authenticate. The user ID length should be the same value that is programmed in the server software. Any place that requires the entry of a user ID will be restricted to the length that is programmed in this area. This value should reflect the amount of users in your terminal. For example, if you have fewer than 100 users than enter 3.
MiKey AC1100 User guide 49 3.6.2. Mobile Key The following window appears if you select the [System] -> [Mobile] in the main menu. Basic system setup can be used to setup the card reader using smart phone administrator application or when using mobile key authentication with the smart phone user application. By default mobile key is enabled. If you do not require any Bluetooth mobile function you can select to disable.
MiKey AC1100 User guide 50 Confirm Bluetooth Registration Select YES Waiting Bluetooth Registration Administrator Mobile App requires login before continuing. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 51 After Administrator Mobile App enters a terminal ID, the registration process is complete. 3.6.3. Face Detection This feature is for detection of a face only; the terminal will not recognize a specific user’s face with this function. This feature can be used for all card users, all mobile users or all password users. After a card, mobile key or password is presented, the terminal will wait up to 10 seconds for a face to appear in front of the camera.
MiKey AC1100 User guide 52 Select the checkbox for authentication types required for a picture during authentication. Card, Mobile Key, Password. By default this feature is disabled. Detection Level When one of the checkboxes above is selected, this defines the detail of facial detection. 1) Level 1 – Basic face , faster 2) Level 2 – Detail face , may take slightly longer Select the [OK] button to save the value or select [BACK] button to cancel and return.
MiKey AC1100 User guide 53 3.6.5. Time/Date If you select the [System] -> [Date/Time] in the main menu, the following window appears. ▶ Time Sync: This is how terminal time/date is updated. - Auto/Server – updated from the server. No need to set Date/Time below. - Manual – set the time/date from this menu and the server will not update the time/date. Note: When connecting with the Bluetooth/mobile key application, the terminal time/date is always updated.
MiKey AC1100 User guide 54 3.6.6. Database If you select the [System]->[Database] in the main menu, the following window appears. ▶ Delete All Users: This option will allow you to delete all users in the system. ▶ Clear Settings: This option will clear/delete all the terminal settings. The factory settings will be used. User, log data and pictures will not be deleted. ▶ Clear Log Data: This option will clear/delete all the log data in the terminal.
MiKey AC1100 User guide 55 3.6.6.1. Database Confirmation ▶ A confirmation window will appear after selecting one of the selections from above. Select YES to continue to delete or NO to cancel. Note: A backup of the user, system settings, pictures or logs should be done before erasing the data. Backup from USB device or system Server device. (USB port is service port.
MiKey AC1100 User guide 56 3.7. Terminal settings 3.7.1. Sounds If you select the [Terminal] -> [Sound] in the main menu, the following window appears. ▶Voice volume Scroll from side to side in to select the appropriate voice setting. A voice will be played after releasing the selector to determine the volume. Slide all the way to the left to disable voice prompts. Default is OFF.
MiKey AC1100 User guide 57 3.7.2. Terminal option If you select the [Terminal]->[Terminal option] in the main menu, the following window appears. ▶ Card Reader If you scan/touch your card to the terminal, the terminal will beep and display the card number. The card number depends on the card format selected from the Card Format option below.
MiKey AC1100 User guide 58 Card format determines how the card data is converted once it is read from the terminal. Note: If you change the card format, you must re-register all card users in the device. When registering a user in the terminal, this value should be set, considered first. Also we registering a user from the server, the card format at the server must match the terminal format. The card number is converted according to the following settings.
MiKey AC1100 User guide 59 If you select the [Terminal] -> [Input] in the main menu, the following window appears. The Terminal has the ability to monitor the physical lock and/or door state when the door is open and closed, or terminal can be used to monitor status of another external device. See the installation guide for details how to connect. ▶ Default Setting : M0-M2 not used, IO (Inside Open) The inputs accept a relay input either Normally Closed or Normally Open.
MiKey AC1100 User guide 60 give an audible warning tone; if any doors are connected to the terminal the terminal will open the doors. When this signal is activated, the server software will also be notified of the fire signal to alert other terminals connected on the network. Wiegand Mode (NC/NO) – If using wiegand output, this input can be used to verify the external controller acknowledged the card data that was sent on the wiegand output. i.
MiKey AC1100 User guide 61 ▶ Default Setting: Same as the window on the left. ▶Lock 1 and Lock 2 Open Time (milliseconds) Lock activation times can be programmed from 300ms to 999999ms. (maximum is 99.999=100 seconds) Lock 1 and Lock 2 Options Not Used – select this option if not using the lock outputs Authorized – select this option if you want to provide an output signal when a user is authorized. i.e.
MiKey AC1100 User guide 62 3.7.5. Terminal Wiegand If you select the [Terminal]->[External device] in the main menu, the following window appears. ▶ Default Setting: Same as the window on the left. ▶Site code It sets the sitecode value sent in Wiegand output below. When the authorization is successful, the data of the following format is sent to the Wiegand port of the terminal. ▶Wiegand Input Standard wiegand is 26 or 34 bit. The terminal is always waiting for wiegand input, up to 34 bits.
MiKey AC1100 User guide 63 3.7.6. Terminal External If you select the [Terminal]->[External device] in the main menu, the following window appears. ▶ Default Setting: Same as the window on the left. See Installation Guide Section 11 for connecting a serial printer. ▶Printer Option Disabled – select this if not using T/A Ticket – if using Time and Attendance mode and require a printout every time authorization occurs. Meal Ticket – if using Meal Mode and require a printout every time authorization occurs.
MiKey AC1100 User guide 64 ▶RS485 Option If ‘controller’ is selected for the RS485 Option, a RS485 is required to connect to a RS485 protocol bus. You should select an appropriate id from 0-7,. Controller selection will work with a standard protocol called ‘OSDP’; this is a SIA Industry standard protocol. Select the [OK] button to save the value or select [BACK] button to cancel and return.
MiKey AC1100 User guide 65 3.8. Display settings 3.8.1. Theme If you select [Display] -> [Theme] in the main menu, the following window appears. ▶ Default Setting: Same as the window on the left. ▶The main background. Main background is displayed on the main window or when screen saver mode is enabled. Cycle forward or back through the available backgrounds. 15 factory set backgrounds are available to choose from. If you import your own background it will also be selectable from this area.
MiKey AC1100 User guide 66 3.8.2. Camera If you select the [Display] -> [Camera] in the main menu, the following window appears.
MiKey AC1100 User guide 67 3.8.3. Language If you select the [Display]->[Language] in the main menu, the following window appears. ▶Default Setting: ‘English’ ▶Language If you change the language and select ‘OK’ button, the voice message and language are changed to the set language. Select [OK] button to apply the changes, or select [BACK] button to cancel and return.
MiKey AC1100 User guide 68 ▶ Default Setting: Same as the window on the left ▶Screen saver (min) (1 minute ~ 30minutes) Select the appropriate timeout you wish to use. If you do not want a screen saver after a timeout select ‘off’. ▶ If screen saver is not set to ‘off’, when this option is unchecked the normal background image will show with the time & date only when the screen saver timeout occurs. When this option is checked the LCD will turn off after the screen saver timeout.
MiKey AC1100 User guide 69 ▶ Default Setting: Same as the window on the left ▶Message display (ms unit) It sets the time for which the authorization result window to be displayed. 0~5000 is available for the value, and the authorization result window appeared and disappear for the duration. Because it is set in ms unit, if you want to set 2 seconds, you should set 2000 ▶Broadcast Message (ms unit) From the UNIS server program you can send a message to the main display.
MiKey AC1100 User guide 70 3.9. Terminal information 3.9.1. System information If you select the [Terminal info] -> [System] in the main menu, the following window appears. ▶System info The hardware and firmware version of the terminal is shown. Card Reader status Camera status Bluetooth status BLE serial number ▶System Storage (using/all) Usage of system data. ▶Ram (use/total) Usage of DDRAM. Select another selection on the left side or CLOSE, BACK button to return to previous window.
MiKey AC1100 User guide 71 3.9.2. Terminal information If you select the [Terminal information] -> [Terminal] in the main menu, the following window appears. ▶Terminal information Displaying basic information about terminal setup Select another selection on the left side or CLOSE, BACK button to return to previous window. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 72 3.9.3. Network information If you select the [Terminal information]->[Network] in the main menu, the following window appears. ▶Network information Displaying basic information about network information. Select another selection on the left side or CLOSE, BACK button to return to previous window. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 73 3.9.4. User information If you select the [Terminal information]->[User] in the main menu, the following window appears. ▶User information - Registered Users: The number of users registered (including administrator) -Administrator Users: The number of the administrators registered. - Card: The number of cards registered Capacity: (Max means the maximum number ) Select another selection on the left side or CLOSE, BACK button to return to previous window.
MiKey AC1100 User guide 74 3.9.5. Log information If you select the [Terminal information] -> [Log] in the main menu, the following window appears. ▶Log Event Log: The number of logs saved in the terminal User Pictures: Number of registered user pictures Log Pictures: Number of log pictures Total Pictures: User and Log picture total Capacity: (Max means the maximum number ) ▶View Log Displays log time and authentication result Select ‘View Log’ to find search results.
MiKey AC1100 User guide 75 3.9.6. About If you select the [Terminal information] -> [About] in the main menu, the following window appears. ▶About Display legal information about software and firmware Select the text area and scroll up or down to view more Select another selection on the left side or CLOSE, BACK button to return to previous window.
MiKey AC1100 User guide 76 3.10. SD USB (USB port is service port.) SD (Storage Device) USB on-The-Go function is supported in the card reader terminal. You will need a cable as shown below. USB storage function will allow you to import and export files to and from the terminal. User data, log data, pictures, images and firmware upgrading can be performed. It is recommended that your USB has at least 1GB available for storage.
MiKey AC1100 User guide 77 Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 78 Filenames maybe in the format. (XXXXXXXX_YYYYMMDDHHMM_ logdata.tar.gz) (XXXXXXXX_YYYYMMDDHHMM.csv) (XXXXXXXX_YYYYMMDDHHMM_ piclogdata.tar.gz) XXXXXXXX = terminal ID YYYYDDMMDDHHMM – Year, Month, Date and Time of export. Note: .tar.gz are tarballed compressed zipped files. If you are using windows PC you may need to download a utility program to extract the files. If you are only saving, and importing to another terminal, you should not rename the file.
MiKey AC1100 User guide 79 ‘CR/data/logpictures’ directory – This directory is created by the card reader terminal when exporting log picture data to the USB device. i.e - 00000008_piclogdata.tar.gz * USB port is service port. ‘CR/unisuser’ directory – This directory is created by the card reader terminal when selecting Export User Data. Files in this directory will be named 0000.dat~9999.dat. These files can be used to import from another device or import to the server program on a PC.
MiKey AC1100 User guide 80 If you select the [SD USB] from the admin menu, the following screen appears. (USB port is service port.) No USB device Connected USB Device Connected with brand name USB Function (USB port is service port.) Import is used to importing user data or system options from another device. Export is used for saving user, event, system options or log picture data. After exporting you may import User data or System Options to another device.
MiKey AC1100 User guide 81 3.11. Background screen change If you select ‘download customized file’ from the UNIS server program you will be able to select ‘All File’. UNIS 4.0 and above only. Select .jpg, .bmp, .png Images only The file name should not exceed 15 letters (English). The file name should be in the format user1-user9.xxx – (xxx=jpg, png, bmp) The file format MUST be an appropriate size to fit the screen 480 x 800. If you select the file type as ‘All File (.
MiKey AC1100 User guide 82 3.20. Language Translations/Customizing Text Items Mostly all text on the user interface can be changed or customized to your customer’s choice. Language must be in the ISO639 format naming is required.
MiKey AC1100 User guide 83 If you select ‘download customized file’ from the UNIS server program you will be able to select ‘All File’. UNIS 4.0 and above only. You can upgrade the new .qm file using the following two ways: 1) USB – see section 3.10. SD USB for updating using USB (USB port is service port.) 2) UNIS – from UNIS, select ‘download customized file’, the select ‘All File(.*)’, browse to the language file and select it. Select OK, and then select the terminal to send to.
MiKey AC1100 User guide 84 4. How to use terminal The background image and composition of the main window can be changed according to the administrator’s setting. In addition, if the administrator set the screen saver time, the LCD screen will show only the background image with the time and date. Entering a card, touching the screen will change back to the main window. 4.1. Authorization mode change ID Input Card Input part
MiKey AC1100 User guide 85 In the access mode selection screen, as shown in the left, select the preferable access mode button, which the screen will move to the selected access mode. 4.2. ID input If you select the [ID input] button on the main window, the following ID input window appears. Enter the user ID to be certified and select [OK] button, and then scan your card or enter your password according to the authorization method of the user.
MiKey AC1100 User guide 86 4.3. Authorization 4.3.3. Card authorization Touch/Scan the card on the area of the card reader as shown in 4.3.4. Password authorization Input your ID by selecting [ID input] button as follows and input password when the password input window appears. Union Community / Hyundai Topics building 5th floor, 44-3, Bangi 2-dong, Songpa-gu, Seoul, Korea (138-050) Tel: 02-6488-3000, Fax: 02-6488-3099, E-Mail:sales@virditech.
MiKey AC1100 User guide 87 FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules.