UBio-X Iris User Guide 55
UNIONCOMMUNITY Co., Ltd.
Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu,
Seoul, Korea (zip code: 05836)
Tel: +82-2-6488-3000, Fax: +82-2-6488-3099,
E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr
[SC card example] Card number (4byte): 52h 9Dh 06h E3h
Card format
Card number
Expression
Standard
529D06E3
8 digits hexadecimal
Hexadecimal E3069D52
8 digits hexadecimal with changing the order of
byte
10 Digit Decimal
1386022627
hexadecimal 529D06E3: 10 digits decimal
3,5 Digit Decimal
3808861522
hexadecimal E3069D52: 10 digits decimal
6 Digit Hexadecimal
069D52
Locate the foremost 3bytes backwards.
Click [OK] button to apply the set value, and click [BACK] button to cancel and return.
3.7.3. Input
If you select the [Terminal] [Input] in the main menu, the following window
appears.
Basic setting: Same with the window at
the left side.
M0: It is set when connecting the external access point to the DM0
(When using motor lock, set [Door Monitor NO] or [Door Monitor NC].)
-None: When nothing is connected.
-Door Monitor NO or Door Monitor NC: When the door open monitoring pin was
connected.
-Fire Monitor NO or Fire Monitor NC: When the fire detection sensor is connected.
-Panic Monitor NO or Panic Monitor NC: When the panic situation detection sensor
is connected.
-Emergency Monitor NO or Emergency Monitor NC: When the emergency situation
detection sensor is connected.
Set NO/NC depending on the state of pin input in detection.
M1/M2: Set when connecting the external access point to DM1/DM2
(When using motor lock, set [Lock Monitor NO] or [Lock Monitor NC].)
- None: When nothing is connected.
- Lock Monitor NO or Lock Monitor NC: When the lock monitoring pin was
connected.
- Fire Monitor NO or Fire Monitor NC: When the fire detection sensor is connected.
- Panic Monitor NO or Panic Monitor NC: When the panic situation detection sensor