User's Guide

Table Of Contents
UBio-X Iris User Guide 58
UNIONCOMMUNITY Co., Ltd.
Addr : 12F, Munjeong Daemyeong Valeon bldg, 127 Beobwon-ro Songpa-gu,
Seoul, Korea (zip code: 05836)
Tel: +82-2-6488-3000, Fax: +82-2-6488-3099,
E-Mail :sales@unioncomm.co.kr; http://www.unioncomm.co.kr
authentication mode are printed by the printer connected to the RS232 port.
The printing format differs as per the setting, and when setting as [Ticket Format
2] the ‘text for meal printer which is set from the terminal option, becomes the title
on the top side. The printer used to print ticket is “SRP-350” serial type model.
RS485: It sets the connecting device to RS485 port.
- None: When there is no device connected to RS485.
- LC010: When LC010 is connected.
- LC015: When LC015 is connected
Site code
It sets the site code value sent in Wiegand output below.
Wiegand Output
It is used only when the special controller is equipped running by the Wiegand input.
When the authentication is finished, the data of the following format is sent to the
Wiegand port of the terminal.
None
General case. It does not use Wiegand out port.
26bit
Because it sends “Site code [1byte] + User ID [2 bytes], set the user
ID less or equal than 4 digits.
Send example) In case of SiteCode:045(2Dh), UID:6543(198Fh)
1 00101101 0001 1001 10001111 0
34bit
Because it sends “Site code [1 byte] + User ID [3 bytes]”, set the user
ID less or equal than 7 digits.
But, if the user ID is 8 digits, ignore site code and send only the “User
ID [4byte]”.
Send example) SiteCode:001(1h), UID:123456(1E240h)
0 00000001 00000001 11100010 01000000 0
Custom
It is set by the user definition, which only can be set in the server, and
the setting type only can be inquired in the terminal.
Click [OK] button to apply the set value, and click [BACK] button to cancel and return.