User's Manual

Smart-i 사용자 가이드 11
㈜유니온커뮤니티 / 서울시 송파구 방이동 44-3 현대토픽스 빌딩 3 (138-050)
Tel : 02-6488-3000 , Fax : 02-6488-3099, E-Mail :sales@unioncomm.co.kr
http://www.unioncomm.co.kr
4.2. Authentication
4.2.1. Card Authentication
Swipe a card on the card input area.
4.3. Control Dip Switch
It has 6 switches, and they are divided in 485 ID Setting (3pole), changing 485 <->
Wiegand (1pole), and selecting BLC015/BLC020/CP040(2pole)
1 2 3
4
5 6
7 8
Functio
n
485 ID Setting
485 <-> Wiegand
BLC015/BLC020/CP04
0
Admin
Not
using
VS-R20 enables to change to Wiegand In mode or to Wiegand Out mode with using SW52.
(Each only supports Mode 1) Please check switch pins when using. When using Wiegand, check
GND pin and DATA1, DATA0 pin (DATA1-DATA1 Connected, DATA0-DATA0 Connected)