M252A INTELLIGENT DOT IMPACT PRINTER Operation manual Rev. 1.
BE SURE TO READ BEFORE USE. Introduction Thank you for purchasing our intelligent printer M252A. This product is to be used by connecting it to our loadcell indicators or digital indicators through the SI/F (two-wire serial interface). External equipment data other than our indicators can also be printed by adding optional BCD input or RS-232C interface. Read this manual and understand the descriptions carefully before use.
SAFETY PRECAUTIONS Be sure to read for safety. In order to have an M252A Intelligent Printer used safely, notes I would like you to surely follow divide into WARNING and CAUTION , and are indicated by the following documents. Notes indicated here are the serious contents related safely. Please use after understanding the contents well. WARNING Misuse may cause the risk of death or serious injury to persons. CAUTION Misuse may cause the risk of injury to persons or damage to property.
WARNING Warning on design ● For the entire system to function safely when the M252A becomes faulty or malfunctions, provide a safety circuit outside the M252A. Warning on installation ● Do not modify the M252A. Doing so may cause fire or electric shocks. ● Do not install in the following environments. - Places containing corrosive gas or flammable gas. - Where the product may be splashed with water, oil or chemicals.
CAUTION Caution on installation ● Do not install in the following environments. - Locations exposed to direct sunlight. - Where the temperature/humidity exceeds the range of the specifications. - Places containing large quantities of salt or iron powder. - Where the main body is directly affected by vibrations or shocks. ● Take adequate shielding measures when using at the following locations. - Near a power line. - Where a strong electric field or magnetic field is formed.
Features of the M252A ■ Dot impact mechanism A 24-digit dot impact type printer mechanism that allows use of copying paper is loaded. ■ Sophisticated statistical computing functions In addition to grand totals and sub totals, maximum, minimum, average, standard deviation, histograms, diagrams, etc., can be printed.
How to review this manual Manual contents are roughly divided into the following six parts. 1 - 3 ..............Safety instructions, installation of the printer, test printing and connections with indicators are explained. Basic use of the printer can be understood. 4 .......................Settings for the printer use are explained. 5 .......................Methods for connecting optional BCD input and RS-232C interface, and method for use are explained. 6 .......................
Contents of the package Item name Quantity M252A printer body 1 Roll paper 1 Ribbon cassette (One is already installed.) 2 AC cable 1 Instruction manual (this book) 1 Mini screwdriver 1 Roll paper installing bar 1 Control signal input connector 57-30500 DDK (attached with BCD input OP) 1 About the power cable ・The power cable attached to this product as standard equipment can be used in the AC100V power supply in Japan.
CONTENTS 1. Before turning on the power .....................1 Name and function of each part ............................... 2 [Front panel] .......................................................... 2 [Rear panel] ........................................................... 3 Front panel key .............................................. 4 2. Printer preparations ............................7 Installing a ribbon cassette ................................. 8 Installing the power cord ......................
08: Automatic Print ON/OFF ............................................ 30 09: Interval Print ON/OFF ............................................. 30 10: Interval Seconds .................................................. 31 11: GT/ST Print Format ................................................ 32 12: Types of Sub Totals ............................................... 34 13,15: Histogram Target Value Ach/Bch ................................. 35 14,16: Histogram Range Ach/Bch ...............................
Maintenance mode ........................................... 63 1: Test Print ......................................................... 65 2: Sample Print ....................................................... 66 3: Self Test .......................................................... 66 4: Parameter List ..................................................... 67 5: Test Mode .......................................................... 67 Over print ..................................................
1 Before turning on the power Explanation of the external appearance of the M252A ■ Name and function of each part ■ Front panel key 2 4 1
1. Before turning on the power Name and function of each part Here, the name and function of each part are simply explained. Detailed explanations of each part are given in its related chapter. [Front panel] ① ② The push panel is open. ③ ④ ⑤ ⑥ Front parts Name Description ① Front panel keys Press when operating and setting the M252A. ② Push panel Open when setting paper or installing a ribbon cassette for the M252A. It pops out approx.
1. Before turning on the power [Rear panel] ⑤ ⑦ ⑨ ⑪ ⑥ ⑧ ⑩ ① ② ③ ④ Rear parts Name Description ① Input terminal block Connect various kinds of inputs. ② Power supply terminal block Connect the power cord. Securely connect the power cord to a power outlet. ③ Option space Install an option to expand the functions of the M252A. Either BCD input or RS-232C interface can be installed optionally. ④ Frame ground (F.G.) Earth terminal. Be sure to ground to prevent electrostatic interference, etc.
1. Before turning on the power Front panel key Key use differs with the modes, but basic use and the meaning of each key, and how to designate it are simply explained below. ① ② ③ ⑫ ④ ⑨ ⑤ ⑥ ⑩ ⑦ ⑧ ⑪ How to designate a key and its function (print mode) Key (how to designate) Description Enters the code input (selection) mode of Ach. ① (Code A) ② (Code B) ③ (Date) ④ (Start) ⑤ (Stop) ⑥ (ST) ⑦ (GT) Prints grand totals. The grand totals and printed counts are cleared, and become 0.
1. Before turning on the power How to designate a key and its function (setting mode) Key (how to designate) ⑥ (Hyphen) ⑦ (SP) ⑧ (No mark) ⑩ (Escape) ⑪ (Enter) ⑫ ~ F 0 (Numerical keys) Description Inputs a hyphen. Inputs a space. Goes to the next input position. Cancels an input value or set value. Accepts an input value or set value. Use for inputting numbers, alphabet and katakana.
1. Before turning on the power Input equivalent circuit A signal is inputted to the signal input circuit by short-circuiting or opening the input terminal and the COM terminal. Short-circuiting is effected by means of a contact (such as a relay or a switch) or a noncontact (such as a transistor or an open-collector TTL). Vcc M252A ← inside outside → Open OFF Short ON +5V approx.
2 Printer preparations Installing a ribbon cassette and roll paper ■ Installing a ribbon cassette ■ Installing the power cord ■ Installing roll paper 8 10 11 7
2. Printer preparations Installing a ribbon cassette Use the PR350/10 (optional accessories) ribbon cassette. Two ribbon cassette are attached (One ribbon cassette has already been installed at the time of delivery.) . Note ■Do not open the front cover with the power on when replacing the ribbon cassette, etc. The printer may start sudden movement, and you may injure yourself. ■Do not drop foreign objects such as screws inside the printer.
2. Printer preparations 2. Open the flip panel downward. Catch the upper left of the installed ribbon cassette with your finger(with your fingernail), and pull and remove it frontward. 3. Install a new ribbon cassette, being careful about its orientation. Turn the ribbon cassette upside down (in the direction that reverses the PULL marking as shown below), and push it in until you hear it click. Then close the flip panel, and push in the push panel firmly until you hear it click.
2. Printer preparations Installing the power cord For connection to terminal blocks, use cables with crimp contacts (M3) as shown in the illustration without unbraiding their ends. AC spec. Connect the AC power cord. The input voltage is 100V - 240V AC. The frequency is 50/60Hz. F.G. AC IN L N F.G. Within 6mm. ■ A parallel two-core power cable with crimp contacts is attached to the product. Note Be sure to ground the F.G. terminal. DC spec.
2. Printer preparations Installing roll paper No roll paper has been installed at the time of delivery. Referring to the following procedures, install roll paper. 1. Push the center (mark) of the push panel with your finger until you hear it click. The push panel pops out forward. And draw out the push panel. 2. Insert the roll paper installing bar into roll paper. Direct the paper winding direction as shown in the illustration, and set it to the bearing.
2. Printer preparations 3. Pass the end of the roll paper under the guide bar at the lower part of the flip panel, and insert it between the guide bar and guide. Press the [FEED] key with the paper inserted, and release the key when the paper comes out of the paper ejection slot. Enlarged section Roll paper ← Front Guide bar Guide 4. Remove the flexure of the roll paper, and push in the push panel firmly until you hear it click.
3 Connecting with indicators ■ SI/F (two-wire serial interface) ■ Connecting through the SI/F ■ Try to print ■ About input ch's ■ Print data input ch's and alarm sound 14 15 16 16 17 13
3. Connecting with indicators SI/F (two-wire serial interface) The M252A is equipped with a SI/F interface to connect it with UNIPULSE-manufactured digital indicators or load cell indicators as standard. In this chapter, connection with indicators through the SI/ F is explained. About the SI/F The UNIPULSE's original SI/F is an interface to connect our F series indicators and printer, or peripheral equipment, such as an external display.
3. Connecting with indicators Connecting through the SI/F The M252A is equipped with a 2-ch SI/F. Parallel two-core cables or captyre cables are adequate for use. The SI/F has no polarity. 1. Strip the casing 0.2in (6mm) on the cable to be connected. 0.2in 2. Twist the bare wire to fit the terminal hole. 3. Insert the supplied screwdriver into the lower hole and lightly hold it down. 4. Insert the twisted wires into the upper hole. 5. Pull the screwdriver out from the lower hole. 6.
3. Connecting with indicators Try to print The M252A prints when any of the following conditions are met. 1. When the [PRINT] key is pressed. (*) 2. When No. 3 (PRINT) and No. 1 (COM) on the terminal block are short-circuited. (*) 3. When an automatic print command is sent from the SI/F. 4. When a print command is input to the RS-232C. 5. At intervals set for interval print. (*) * In the cases of 1, 2 and 5, the M252A does not print if no print data is input.
3. Connecting with indicators Print data input ch's and alarm sound In the case of single print In the case where the input ch setting is single print (the [Print Every Format] setting is not double print), if printing is attempted without print data input from Ach or an optional interface, the alarm (buzzer) will sound, resulting in error printing.
3.
4 For greater use of the printer Explanation of each setting ■ Basics of settings ■ Details of each setting 20 24 19
4. For greater use of the printer Basics of settings Mode configuration of the M252A The M252A consists of four modes. See the "Setting mode list"(page 80). When A key is pushed, “Quit" is printed. + Setting mode Printer settings are made in this mode. F 0 + Printing is produced in this mode. The M252A starts with this mode after power is turned on. When Select Print mode Option setting mode + Option settings are made in this mode. You cannot enter this mode if no option is equipped.
4. For greater use of the printer Basic operation of settings The basic operating procedures for actually making settings of the M252A are described below. Here, the "Automatic Print ON/OFF" setting is made as an example. 1. Press [F] → [ENT], and the following is printed. To enter the setting mode, press [1] → [ENT] successively.
4. For greater use of the printer 3. Upon entry of the Automatic Print ON/OFF setting, the following is printed. The current set value is indicated on the "NOW" line. End --> Next --> Change-> --> Current set value ESC Number-ENT ENT Now => ON 08:Automatic Print ------------------------->> Next is 08 The current value is "Automatic Print ON". Change the set value to "OFF". To make the Automatic Print setting: operating [ENT] To make other settings: [Setting No.
4. For greater use of the printer 5. The changed set value is printed. End --> ESC Next --> Number-ENT Change --> ENT This part is for the next setting (09 : Interval Print ON/OFF). NOW ==> Off 09:Interval Print On/Off -------------------------New ==> Off Changed set value After changing the setting, go to the next setting (step 2 and 3). To make the Interval Print ON/OFF setting: [ENT] To make other settings: [Setting No.
4. For greater use of the printer Details of each setting The details and operating method of each setting are explained below. For how to enter the setting mode and its operating method, see the “Basics of settings” described in the previous chapter. 01: Date/Time Change the date and time. The date and time of the M252A are factory-set. Correct it when it is necessary. Name of setting Initial value Input format 01: Date/Time The current time has been set at the time of delivery.
4. For greater use of the printer 02, 03: Print Data Selection Ach/Bch Select the type of data to be printed for each ch. Four types of data can be selected. Name of setting Selection item Reference Caution 02: Print Data Selection Ach 03: Print Data Selection Bch 0. Gross (initial value) 1. Net 2. Tare 3. Indicated ・When printing values indicated by load cell indicators, normally set the M252A at [3. Indicated]. Select Gross, Net or Tare only when you want to specifically print these.
4. For greater use of the printer 04, 05: Unit Selection Ach/Bch Select the unit to be printed on Ach/Bch. 43 types of data can be selected. Name of setting Selection item Initial value Caution 04: Unit Selection Ach 05: Unit Selection Bch See the "List of unit settings"(page 82). 02. kg When "Double size" is selected under Print Every Format, the unit is printed only up to four characters. If a unit of five or more characters is selected, only the first four characters are printed.
4. For greater use of the printer 07: Print Every Format Select the print format of data. 13 types of print format can be selected. Name of setting Selection item Reference Caution 07: Print Every Format 0. Standard (initial value) 1. With time 2. With code 3. With time & code 4. With date 5. With date & code 6. Diagram 7. Double size 8. Double print 9. Double with cnt 10. Double with code 11. Ach <-- A or B 12.
4. For greater use of the printer Examples of print 0. Standard (count, data) Count input data Time Count 1503 1502 1501 1500 1499 1498 1497 1496 500.5kg 450.2kg 1200.0kg -385.8kg 55.0kg 0.0kg 1000.2kg 666.6kg 14:30 14:22 14:00 13:48 12:11 10:03 9:20 6:05 1503 1502 1501 1500 1499 1498 1497 1496 2. With code name (code name, count, data) Code name FGHI FGHI JKLM FGHI NOPQR JKLM NOPQR STUV Count Input data 7503 7502 2002 7501 1502 2001 1501 1001 500.5kg 450.2kg 1200.0kg -385.8kg 55.0kg 0.
4. For greater use of the printer Examples of print 7. Double size print (data) 6. Diagram Input data Displacement diagram Upper limit 500.5kg 450.2kg 1200.0kg -385.8kg 55.0kg ▲ -0.2 48.7 78.5 102.1 { Example Target Value ▲ Lower limit Input data Input data is printed horizontally double size. However, the unit can be printed only up to four characters. TARGET: 50.0kg RANGE: 50.0kg 9. Double print with count 8. Double print Ach input data Bch input data Count 389.3kg 500.0kg 46 78.
4. For greater use of the printer 08: Automatic Print ON/OFF Printing can be automatically produced by sending a print command from the SI/F or RS-232C interface to the M252A. Select whether this Automatic Print is ON or OFF. Name of setting Selection item 08: Automatic Print ON/OFF 0. OFF 1. ON (initial value) Caution ・Printing is always produced in the following conditions irrespective of whether Automatic Print is ON or OFF. ・When the [PRINT] key is pressed.
4. For greater use of the printer Details of settings ON........................... Print is automatically produced at intervals of seconds set under [10: Interval Seconds] (See below). Printing is not produced with a print command from the SI/F or RS-232C interface. OFF......................... Interval Print is not performed. Timing of Interval Print * Setting Interval Seconds at 5 seconds. Interval Print Start 5sec. 5sec. 1st time End 5sec.
4. For greater use of the printer 11: GT/ST Print Format Select the print format of grand totals and sub totals. Five types of formats can be selected. Name of setting Selection item Reference 11: GT/ST Print Format 0. Standard (initial value) 1. With code 2. With ave/max/min 3. With statistical 4. With histogram If Double print is selected under [Print Every Format] and Ach and Bch are the same in unit, the grand total all of both ch's is printed after printingthe total of each ch. Examples of print 0.
4. For greater use of the printer Examples of printing 4.
4. For greater use of the printer 12: Types of Sub Totals Select the types of sub totals. There are two types of sub totals: Middle and Section. Name of setting Selection item 12: Types of Sub Totals 0. Middle sub (initial value) 1. Section sub Details of settings Middle sub ............. A middle sub total from the last total to this sub total is printed. 0 100 250 300 500 400 Printing count ST GT 100times ST 250times ST 400times ST 500times ST 300times Section sub total ....
4. For greater use of the printer 13, 15: Histogram Target Value Ach/Bch 14, 16: Histogram Range Ach/Bch * These setting items also serve as the "Range over (U/L)" setting (page 69). Set the target value and range (width from the target value) necessary to work out statistical data and the histogram.
4. For greater use of the printer Example of setting -Setting the target value at 100 and the range at 20- Lower Target limit value Upper limit L print 55.0kgL etc 0 U print 150.0kgU etc 80 100 120 Example of noprinting -Setting the target value at 80000 and the range at 19999- Lower Target limit value L print 60000kgL etc 0 36 60001 Upper limit ( 80000 99999 No U print More than 99999 cannot be printed.
4. For greater use of the printer * This setting item is necessary when the GT/ST Print Format setting is 2 - 4. 17: Standard Deviation Select a standard deviation calculating expressions. There are two types of calculating expression. Name of settings Selection 17: Standard Deviation 0. σn (initial value) 1. σn-1 Details of settings σn ........................... When all data in a group is used, and the standard deviation of the group is obtained.
4. For greater use of the printer 18: Data Adding ON/OFF Select whether or not the print data is targeted for grand totals/sub totals. Name of setting Selection item Caution 18: Data Adding ON/OFF 0. OFF 1. ON (initial value) If Data Adding OFF is selected, printing is produced irrespective of the setting of [06: Print Every ON/OFF]. Details of settings ON........................... The print data is targeted for grand totals/sub totals. OFF.........................
4. For greater use of the printer 20: Batch Total ON/OFF Set whether or not to find the batch total. If Batch Total is selected, the [FEED] terminal block on the rear panel is switched to the [Batch Total Print] terminal block. Name of setting Selection item 20: Batch Total ON/OFF 0. OFF (initial value) 1. ON Caution ・Batch Total can only be executed by short-circuiting [FEED] and [COM] on the rear terminal block. ・If Double print is set, Batch Total cannot be turned ON.
4. For greater use of the printer 21: Feed Lines Set the number of lines for feeding paper after Print Every, ST (sub total print) and GT (grand total print). Name of setting Setting range Initial value Caution 21: Feed Lines 0 - 9 (lines) 0 Paper is fed by the number of lines set under [Feed Lines] after Print Every, ST, GT, BT, Sample Print and Test Print. Paper is always fed by one line with the [FEED] key.
4. For greater use of the printer 23: Number of Code Digits Designation Set the number of code digits for classification. Name of setting Setting range Initial value Caution 23: Number of Code Digits Designation 0 - 6 (digits) 6 When using code tables, set the Number of Code Digits to two digits. If it is set to three or more digits, normal classification cannot be performed.
4.
5 Optional interface BCD input and RS-232C interface ■ BCD input (option) ■ BCD input settings ■ RS-232C interface(option) ■ RS-232C settings ■ Communications format ■ DC power source 44 48 49 50 52 54 43
5. Optional interface BCD input (option) The BCD input is an interface to take in BCD data, and code numbers to the M252A. Applicable connector Input data Input equipment Input logic DDK-manufactured 57-30500 or equivalent Print data, codes (number, space, hyphen) Digital switch, DIP switch, BCD output equipment, etc. Select negative logic or positive logic.
5. Optional interface Codes for BCD data input Binary number MSB LSB Hexadecimal number Print Character 0000 0 0 1001 1010 1011 1100 1101 9 A B C D 9 Space Space Space 1110 1111 E F ‐ (Hyphen) Space Space Note - When you input a code from BCD input, please choose 1or 3 of setting item "code selection ". - When you make a code print by print every format, please choose thing with a code. By the default, only the count and data are displayed.
5. Optional interface Input equivalent circuit A signal is inputted to the signal input circuit by short-circuiting or opening the input terminal and the COM terminal. Short-circuiting is effected by means of a contact (such as a relay or a switch) or a noncontact (such as a transistor or an open-collector TTL). M252A Vcc ← inside outside → Logic Negative Positive +5V Open OFF ON Short ON OFF approx. IC=0.
5. Optional interface Read command Valid data Data Valid data MAX. 5ms MAX. 5ms MIN. 15ms MIN. 15ms OFF ON MIN. 10ms MIN. 10ms When ON continues for 1 sec or more OFF ON Read command Approx. 100 100 100 100ms 100 100 100ms Approx.
5. Optional interface BCD input settings 41: BCD Decimal Point Position Select a decimal point position to input data through the BCD input. Five types of decimal point positions can be selected. Name of setting Selection item 41: BCD Decimal Point Position 0. *.**** 1. **.*** 2. ***.** 3. ****.* 4. ***** (initial value) 42: BCD Data Logic 43: BCD Minus Logic 44: BCD Over Logic 45: BCD Strobe Logic Select a BCD input logic.
5. Optional interface RS-232C interface(option) The RS-232C is an interface to take in RS-232C spec data, codes and command signals to the M252A. Signal level Transmission distance Transfer system Transfer speed Bit configuration Code Connector Necessary settings RS-232C spec Approx.
5. Optional interface RS-232C settings 46: RS-232C Transmission Rate Select transmission rate Name of setting Selection item Caution 46: RS-232C Transmission Rate 0. 1200bps 1. 2400bps 2. 4800bps 3. 9600bps (initial value) The setting must be the same as the connecting equipment. 47: RS-232C Parity Bit Select parity bit. Name of setting Selection item Caution 47: RS-232C Parity Bit 0. Even 1. Odd (initial value) 2. Non The setting must be the same as the connecting equipment.
5. Optional interface 49: RS-232C Terminator Select terminator. Name of setting Selection item Caution 49: RS-232C Terminator 0. CR 1. CR+LF (initial value) The setting must be the same as the connecting equipment. 50: RS-232C Answer Mode When receiving data or a command through the RS-232C interface, the M252A returns with the received data or command to the host computer. Select this return format. Name of setting Selection item Reference Caution 50: RS-232C Answer Mode 0.
5. Optional interface Communications format The M252A receives all data through the RS-232C as character strings consisting of ASCII characters. For data and command formats, see below. Data (without automatic print) F A 0 ± 9 9 9 . 9 9 CR LF Command 5 digits + decimal Terminater point Sign * If no decimal point is included, 0 is added to the uppermost digit. Data (automatic print) F A 1 ± 0 9 9 .
5. Optional interface Delete last data F B 0 CR LF GT print F B 1 CR LF ST print F B 2 CR LF Data print (latest data print) F B 3 CR LF Paper feed F B 9 CR LF Batch total print F B 4 CR LF Date/Time print F B 6 CR LF Note - When you input a code with RS-232C interface, please choose 1or 3 of setting item "code selection ". - When you make a code print by print every format, please choose thing with a code. By the default, only the count and data are printed.
5. Optional interface DC power source For the M252A, DC power source specification can be selected at order-time. + - DC IN Red Black Connect the positive (+) side of the power source to the red screw side of the terminal block on the back of the M252A, and its negative (-) side to the black screw side. Input voltage range DC12V ~ 24V +15% -15% (voltage between terminals of the M252A) Note Be aware that the voltage drops depending on the wire thickness and length.
6 Advanced use Various functions of the M252A ■ Classification by code name and code table ■ Maintenance mode ■ Over print ■ Delete print ■ Initialization ■ ROM version print ■ Date print 56 63 68 70 71 71 72 55
6. Advanced use Classification by code name and code table The M252A can total sub totals and grand totals on the basis of code names assigned to print data. Up to 32 code names can be registered for each ch. Maximum number of 32 code names for each ch code names Method of registration ・A registration waiting state is developed by inputting with front panel keys and pressing Input format Usable characters Code name designation method [A] → [ENT] ( [B] → [ENT] on Bch). ・Input through the RS-232C.
6. Advanced use Code name registration performance with front panel keys Input code names by using numeral keys from [1] to [0], and [-(ST)], [SP(GT)], [(DEL)] keys. Since each numerical key is assigned approx. 10 characters, press the key until a desired character is displayed results. (This is designateed a key group.) For the list of characters assigned to each group, see the appendix "Character input table"(page 83).
6. Advanced use Code table - Difference from code names By registering code names corresponding to 2-digit numbers (code table numbers) between 00 and 31 beforehand (The same also applies to Bch.), a registered code name can be designated and printed by specifying its table number without inputting its code name every time you select a code name. If the code table is not used, it is necessary to designate the code name by inputting it with front panel keys or through an option.
6. Advanced use Code table registration performance Code table registration is almost the same as the abovementioned [Code name registration performance] except for inputting table numbers corresponding to code names at the beginning. The basic operating procedures actually for setting the M252A are described below. Here, the code table number "01" and code name "NOPQR" are registered on Ach as an example. 1. Select “2. Key Table” or “3. Option Table” under [22: Code Selection Method]. 2.
6. Advanced use 5. Since the following is printed, input the code name successively. operating >> Input code name - ENT >> Now Code [GH ] >> Table number is 01 Registered table number Referring to [Code registration performance], input the code name. 6. The registered code name is printed, and code table registration is completed.
6. Advanced use How to designate a code name/code table For designating a code name, input the code name, and for designating a code table, input the table number. There are some restrictions in interface for designating a code name/code table. Select whether to designate a code name or code table and whether to use front panel keys or an optional interface under [22: Code Name Selection Method] in the setting mode.
6. Advanced use Note Be careful when over 32 types of codes or other than 00~31 codes is selected from front panel or option,accumulation is conducted taking items below as selected Code: Code printed first after calculated GT Example) When 000032 is selected after 32 types of code 000000~000031 were printed. Input After calculated GT. Accumulation is conducted taking the code first printed as selected. In this case 000005 is selected.
6. Advanced use Maintenance mode In the maintenance mode, operations of the M252A are checked. 1 Test Print All characters that can be printed by the M252A are printed. The data input status is printed. Print Every and GT/ST Print formats are printed. 2 Sample Print 3 Self Test The ROM and RAM of the M252A are tested, and the results are printed. A list of current parameters of the M252A is printed. 4 Parameter List 5 Test Mode For factory check (Do not use).
6. Advanced use 2. Since a list of items in the maintenance mode is printed, select a target item.
6. Advanced use 1: Test Print All characters that can be printed with the M252A, and the input data/status of each I/F are printed. Test print is executed by pressing [1] → [ENT] in the maintenance mode. Sample of printing Strobe ON Strobe OFF Code input Print data input T: Over OFF O: Over ON Built-in font Input data/status The SIF Bch status is printed only for double printing. For BCD, printing results only when a BCD option is attached. The data input status from the BCD IN connector is shown.
6. Advanced use 2: Sample Print Print Every and GT/ST Print formats are printed. Test print is executed by pressing [2] → [ENT] in the maintenance mode. Sample of printing (partial) (↑ Print continues.) ************************ ** SAMPLE PRINT No.3 ** ************************ A---00 9876 12345kg ************************ ** SAMPLE PRINT No.2 ** ************************ 05:09 9876 12345kg ************************ ** SAMPLE PRINT No.
6. Advanced use 4: Parameter List A list of current parameters of the M252A is printed. If a code table is used, code table setting values are also printed. Sample of printing (↑ Print continues.) kg 04:Unit Selection Ach Gross 03:Print Data Bch Gross 02:Print Data Ach 2000/07/01 05:11 01:Date/Time ************************ ** PARAMETER LIST ** ************************ ■ As a parameter list, 100 lines are printed in total (approximately 35cm).
6. Advanced use Over print Print data out of the range set by the connecting indicator or the M252A is identified by this function. There are two types of over print: over status (R) and range over (U/L). Over status (R) If the indicator side causes a LOAD (A/D converter input over), OFL1 (net>99999) or zero abnormality, "R" is added after printed data, and the data is not added to grand totals/sub totals. It is not counted up either.
6. Advanced use Range over (U/L) If the range set under Target Value Ach (Bch) and Range Ach (Bch) is exceeded, the print is added after printed data. If the upper limit is exceeded, "U" is printed, and if the lower limit is exceeded, "L" is printed. (Example) When the target value is set at 100, and the range at 20. Lower Target limit value L print 55.0kgL etc 0 Upper limit ‘U’ print Measurement value > Target value + Range U print 150.
6. Advanced use Delete print Use if you want to delete printed data (when you do not want to add the data to subtotals/grand totals). Only one piece of the last printed data can be deleted. Press [DEL] → [ENT] in the print mode, and the data is deleted.
6. Advanced use Initialization The internal memory of the M252A is completely cleared, and the parameters are restored to their factory default settings. 1. Turn on the power while pressing the [A] key. 2. Since the following is printed, press [ENT]. Cancel --> ESC OK --> ENT ----All data initial---- operating To execute initialization: [ENT] To cancel initialization: [ESC] 3. If the following is printed, initialization is successful.
6. Advanced use Date print Press [DATE] → [ENT] in the print mode, and the current time is printed.
7 Troubleshooting ■ Classification of trouble ■ The printer does not operate properly ■ The printer does not function properly ■ Others 74 75 77 78 73
7. Troubleshooting Classification of trouble Find applicable trouble out of the following, and take remedies according to the reference page. If printing still cannot be generated properly, check the ROM version of the M252A body (See page 71) and contact us. The printer does not operate properly. The M252A does not start............................................................................................. P.71 Printing is not generated...............................................................
7. Troubleshooting The printer does not operate properly Trouble 1 The M252A does not start. Cause 1 The M252A is not connected to a power source. Remedy1 Check that the power cord is fixed properly. Cause 2 If the power LED does not light even though the M252A is connected to a power source, the fuse may have blown. Remedy1 Since the fuse has been installed inside the M252A, disassembly is necessary for replacement. Therefore, it should be replaced by UNIPULSE.
7. Troubleshooting Cause 3 The printer is clogged with dust or jammed with paper. Remedy1 Open the push panel, and check the mechanical part of the printer. Remove dust with air or the like. Remedy2 In the case of a paper jam, the printer is locked, so that [Print] and [Feed] cannot be used. It may cause some trouble if you pull the paper fast or backward when you remove the paper. Please pull the paper forward slowly and straight to remove it after stopping the paper feed.
7. Troubleshooting The printer does not function properly Trouble 1 Cause 1 Printed counts are wrong. Counts are stored in battery-required memory. If the power is turned off and on again with the battery exhausted, a problem occurs such that printing is not counted normally. Remedy1 The battery needs to be replaced. Since the battery should be replaced by UNIPULSE, contact your dealer representative. The average life of the battery is approx. 8 years.
7. Troubleshooting Others Trouble 1 Remedy1 Printing has been generated by mistake. The last piece of printed data can be deleted by delete print. For the details, see "Delete print"(page 70). Trouble 2 Cause 1 The target value cannot be set. The setting cannot be made if the total of the absolute value of the target value and the range exceeds 99999. Remedy1 Since the initial value of the range is 99999, the target value cannot be set in a initial state.
7. Troubleshooting Cause 2 In Print- Every, Warning (Buzzer) will sound if number of code in each channel exceeds 32. In this case, Count to first code after GT Print, and print the code. Remedy2 Please operate each channel with 32 code or less. When the GT Print is done, the number of code is reset to 0.
7.
Appendix ■ Setting mode list ■ Option setting mode list ■ Maintenance mode list ■ List of unit settings ■ Character input table ■ List of error messages ■ Introduction of consumables and options ■ Product specifications of the M252A ■ External views 82 83 84 84 85 86 87 88 90 81
Appendix Setting mode list No.
Appendix No. Name of setting Details of setting Page 20 Batch Total ON/OFF 0. OFF 1. ON 37 21 Feed Lines 38 22 Code Selection Method 0 ~ 9 (Initial value of 0) Ach 0. Key Board 1. Option 2. Key Table 3. Option Table 38 Bch 0. Key Board 1. Key Board 2. Key Table 3. Key Table 23 Number of Code Digits Designation 24 25 Code Table Registration Ach Code Table Registration Bch 1 ~ 6 (Initial value 6) 39 39 39 Option setting mode list No.
Appendix Maintenance mode list No 1 2 3 4 5 Name of setting Page Test Print Sample Print Self Test Parameter List Test Mode 60 60 61 61 61 List of unit settings NO.
Appendix Character input table Key 2 3 1 A B 2 C D E 3 F G H 4 I J K 5 L M N 6 7 O R 4 P Q S T 8 U V W 9 X Y Z 0 ー / * 10 5 6 7 8 9 ア イ ウ エ オ ※ ※ ※ ※ ※ カ キ ク ケ コ ※ ※ ※ ※ ※ サ シ ス セ ソ ※ ※ ※ ※ ※ タ チ ツ ッ テ ト ※ ※ ※ ※ ※ ※ ナ 二 ヌ ネ ノ ※ ※ ※ ※ ※ ハ ヒ フ ヘ ホ ※ ※ ※ ※ ※ マ ミ ム メ モ ※ ※ ※ ※ ※ ヤ ャ ユ ュ ヨ ョ ※ ※ ※ ※ ※ ※ ラ リ ル レ ロ ※ ※ ※ ※ ※ ワ ヲ ン ゛ ゜ ※ ※ ※ ※ ※ Back to the first
Appendix List of error messages Error1 This error is printed if [Print Every Format] is selected when the [Print Every] setting is OFF. ⇒ Check the set value of [06: Print Every ON/OFF] (page 26). Error2 This error is printed if [Batch Total] is turned ON when the [Print Every Format] setting is "Double print", "Double with count" or "Double with code". ⇒ Check the set value of [07: Print Every Format] (page 27).
Appendix Introduction of consumables and options PR350/10 (10 pieces in a set) Ribbon cassette (consumable) PP350/10 (10 rolls in a set) Width: 57.5 ± 0.
Appendix Product specifications of the M252A Printer section Printing system Print speed Number of print digits Ink ribbon Printing paper 5 × 7 dot impact system Approx. 2.5 lines/sec. (approx. 60cps) 24 digits Ribbon cassette Roll paper (PP350) width: 57.5 ± 0.5mm, diameter: 60mm, overall length: 30m) Number of printable lines: Approx. 8,000 lines/roll Duplicate roll paper (PP350-2P) width: 57.5 ± 0.5mm, diameter: 60mm, overall length: 20m) Number of printable lines: Approx.
Appendix Interface Rear terminal block (6-7) SI/F-Ach, (8-9) SI/F-Bch Option BCD input interface Connector: DDK-manufactured 57-30500 or equivalent Option RS-232C interface Connector: D-Sub 9pin (CN33) General performance AC Spec. DC Spec. (Dependi ng on the request at the time of order) Power supply voltage 100V to 240V AC (+10%, -15%) Power consumption On standby: Approx. 2.8VA During print: 20VA (maximum), Approx. 8VA (average) Inrush current 15A (5msec): 100V AC max.
Appendix External views 90