Use and Care Manual

23
30” MODEL
GAS RANGE CONVERSION (continued)
ATTENTION: YOUR PRODUCT IS PRE-INSTALLED WITH NATURAL GAS INJECTORS
AND REGULATOR.
IF YOU ARE USING LP GAS, PLEASE REFER TO THE INSTALLATION INSTRUCTIONS
INCLUDED WITH THE CONVERSION KIT.
Convertible Pressure Regulator
The range is shipped to operate on NG. LPG orifices
for adjusting the minimum flame are shipped with the
unit in a separate envelope with the manual. The inlet
pressure of the gas supply shall be in accordance with
the nominal inlet pressure of the regulator used on the
range or ½ psig maximum. The range should be tested
by pressurizing the regulator with an inlet pressure at
least 1” water column above the manufacturers specified
manifold pressure shown on the serial plate.
ORIFICES
1. CAUTION: Before proceeding with the
conversion, shut o the gas supply to
the appliance prior to disconnecting the
electrical power
2. Locate convertible regulator at the back
of the range, left side facing back of
appliance. Unscrew cap to locate pin.
3. On the side of the pin you will see the
respective marking for LPG and NG.
4. Unscrew pin and flip it to the LPG position (arrow facing cap indicating correct
setting)
5. Replace the cap back on the regulator
Top Burner Orifices
6. Remove the grates, burners and burner caps from the
range to access the orifices.
7. Use a 7 mm wrench to remove the orifices. Each
orifice can be accessed easily - the larger burner
orifice is located on the burner wall.
BURNER ORIFICE
ORIFICE LOCATION
LPG NG