Installation Guide

23
10. Take the NG orifices provided and install them as shown below
See below for rating of orifice for each model
11. Once all the orifices are installed, replace all burners and burner caps, then fire up
the burners to check the minimum flame height.
12. Minimum flame height should be approx. ¼” tall. There is a small adjustment screw
located on the valve itself. The lid and the front control panel must be removed to
accomplish this adjustment.
13. Turn the valve fully counter clockwise. Then proceed to adjust the adjustment screw
counter clockwise for a smaller flame and clockwise
for a larger flame. Adjustment: Minimum flame should
be approx. ¼” tall.
14. Temporarily replace the lid, burners, burner caps
and grates and recheck the flame. Once complete,
reassemble the control panel and the lid.
15. Next, the oven orifice needs to be replaced.
16. Remove all racks, then the bottom pan by lifting up
the back first to release the front then pull pan out.
17. Locate the burner tube and locate the retaining screw at the front of the tube. Once
this screw has been removed, lift up the burner and pull away slightly to the right to
expose the oven orifice.
GAS RANGE CONVERSION (continued)
FLAME HEIGHT ADJUSTMENT
Adjustment location is
inside the valve stem
Adjustment location is inside the
valve stem
Natural Gas Orifices
BTU 13,000 10,000 3,200 10,000 13,000
BURNER Triple Burner Semi-Rapid
Burner
Simmer
Burner
Rapid Burner Oven Burner
POSITION Front Right Rear Left Rear Right Front Left
ORIFICE 0.68 1.28
x2
1.50 0.90 1.50 1.9
Liquid Propane Gas Orifices
BTU 14,000 9,000 3,200 9,000 13,500
BURNER Triple Burner Semi-Rapid
Burner
Simmer
Burner
Rapid Burner Oven Burner
POSITION Front Right Rear Left Rear Right Front Left
ORIFICE 0.53
0.77
x2
0.93 0.57 0.93 1.12