Chapter 6 Maintenance
6.4 Preventative Maintenance
The only required preventative mai
ntenance is for the HPA compartment air intake filters
and the air-to-air heat exchanger/heater exterior coils.
As a general rule, it is recommended that the air filters and exterior coils be cleaned every 6
months under normal conditions, or every 3 months in dusty environments. UBS would
recommend that the filters and exterior coils be inspected more frequently and cleaning
intervals be adjusted as deemed necessary by the operator.
6.5 Replacement Procedures
The following repeater components
can be replaced:
Table 6-2 Replaceable Components
Electronics Compartment Part Number
PDU Circuit Breaker N/A
PDU Current Sensor N/A
BMS Mounting Shelf w/Controller SX03-50310-01
BMS 12 VDC Rectifier Module SX03-50320-01
BMS 12 VDC Battery SX03-50330-01
Dual Band Pass Filter (DBPF) SX03-50100-01
Low Noise Amplifier (LNA) SX03-50200-01
TSC SX03-50700-01
LBD DR Filter SX03-51100-01
HBE N/A
LBE N/A
TRMS N/A
Air-to-Air Heat Exchanger/Heater SX03-50400-01
HPA Compartment Part Number
High Power Amplifier (HPA) SX03-40000-01
HPA PSU Mounting Shelf SX03-51710-01
HPA PSU 30 VDC Rectifier Module SX03-51720-01
4-Way Hybrid Combiner SX03-21806-01
1000W Termination 000087206R
500W Termination 000051005
500W Termination #1 Heat Sink SX03-21781-01
500W Termination #2 Heat Sink SX03-21782-01
SX03-2000