2.6 Power Supply
Power Supply
Voltage 190 – 264 VAC (208 VAC nominal),
Single Phase, 4 wire (L1, L2, N, G)
Frequency 47 to 63 Hz
Power Consumption Overall: max. 19.2 kVA
HB Cabinet: 10.1 kVA
LB Cabinet: 9.1 kVA
2.7 Environmental
Environmental
Ambient Operating Temperature -4°F to +131°F (-20°C to +55°C)
Ambient Storage Temperature -22°F to +167°F (-30ºC to +75ºC)
Operating Humidity 5% to 95%, non-condensing
Storage Humidity 5% to 99%, non-condensing
Altitude max. 5500 ft. (1676 m)
Electronics Compartment Cooling Air-to-Air Heat Exchanger
Electronics Compartment
Inside Temperature
14°F to +149°F (-10°C to +65°C)
HPA Compartment Cooling Forced Air, 2800 CFM
HPA Compartment
Inside Temperature
-4°F to +131°F (-20°C to +55°C)
Total DRU Heat Dissipation 54,000 BTU (Exhausted + Radiated)
Note: Radiated heat (into room) is equal to
15% of dissipated heat.