Chapter 3 Installation
SX03-20000-01-M01 3-49
3.16.3 Repeater Cabinet AC Power Connection
Figure 3-43
depicts the recommended repeater AC power connection.
Figure 3-43 AC Power Cable Routing
Repeater Pedestal
SiriusXM
DRU-1k
HB or LB Cabinet
PDU
Electrical Conduit
or BX Cable
AC Disconnect
Electrical Conduit
or BX Cable
Arrange for the installation of two (2) AC disconnect device on the repeater pedestal or
in close proximity to the repeater cabinet. The AC disconnect device must be
connected to the building/site electrical service panel according to all local and
national electrical codes.
Two (2) AC power cables should be run to meet all local and national electrical codes,
and according to the repeater electrical drawing(s). This may require the cables to
be run inside electrical conduit between the building/site electrical service panel and
the repeater cabinets.