User's Manual

Chapter 4 Commissioning
4.4 Commissioning Procedure
Duri
ng the commissioning (initial turn-on) procedure, the operator will be required to
perform the following tasks:
1. Power-on the repeater
2. Configure the repeater
3. Place the repeater in broadcast mode
4.4.1 Repeater AC/DC Power-on
The rep
eater is divided into separate LB and HB cabinets. However, there are several
components (assemblies) which are shared by both cabinets, but are physically located in
only one of the cabinets. In this case, it is recommended that the HB sub-system is turned on
before the LB sub-system is turned on.
4.4.1.1 Main Disconnect
T
he repeater AC/DC power should be turned on in the following sequence:
1. Switch ON the repeater circuit breaker, located in the building/site electrical service
panel.
2. Switch ON the AC disconnect device, located on or near the repeater pedestal (where
applicable).
SX03-2000
0-01-M01 4-2