User's Manual

Chapter 3 Installation
3.9.2 High Band Exciter (HBE)
During the
installation procedure, a number of wires/cables must be connected to the HBE
rear panel. Please refer to Table 3-6
or drawings SX03-30900-02-D06 or SX03-30900-03-
D06.
The cables should be connected in the order that they appear in Table 3-6
.
Figure 3-34 HBE Rear Panel
Table 3-6 HBE Rear Panel Connections
HBE Port Name Type Cable Number
N/A N/A Ground Post SX03-33937-03
CJ02 TEMP
SENSORS
DB-25 (F) SX03-33917-01
CJ03 HPA/KPA1 DB-9 (F) SX03-33919-01
CP02 OPA DC PS DB-25 (M) SX03-33911-01
RJ02 WAN RJ-45 SX03-33901-03
RJ03 LAN RJ-45 SX03-33901-02
DJ06 LNA PWR 4-pos CPC SX03-33906-01
CJ08 DC POWER 14-pos CPC SX03-33908-01
DJ02 RF IN SMA (F), 50 ohm SX03-33941-01
DJ05 ANC IN SMA (F), 50 ohm SX03-33920-01
DJ03 RF OUT SMA (F), 50 ohm SX03-33924-01
SX03-30000-01-M01
3-38