Chapter 3 Installation
3.14 RF Output Interfaces
Opening RF lines during operation may cause electric arcs that can
cause burns and eye injuries. RF output ports 1 and 2 must be
terminated into a broadcast antenna or test load.
The DRU-2KW includes two (2) RF output ports, which are located on the OFN cabinet top
panel.
During the installation procedure, these outputs must be terminated into a broadcast
antenna or test load.
3.14.1 Configuration
The HB, LB
and LBD
transmit signal mapping depends on the DRU configuration – see Table
3-14
.
Table 3-14 RF Output Mapping
Port Combined DRU Independent DRU
Output 1 HB and LB HB and LBD
Output 2 LBD LB
Figure 3-51 Combined DRU RF Output Ports
1) Output 1 (Combined RF Output Port) – WR340 Flange
2) Output 2 (Independent RF Output Port ) – 7/8” EIA Flange
SX03-30000-01-M01