User's Manual

Chapter 4 Commissioning
32. Switch ON the HPA 2 PSU circuit breaker (CB2), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 3 PSU (PS 2) Norm LED is blinking green.
o Ensure that the LB HPA 3 PDU (PS 2) Alarm LED is blinking red.
33. Switch ON the HPA 3 PSU circuit breaker (CB3), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 4 PSU (PS 3) Norm LED is blinking green.
o Ensure that the LB HPA 4 PDU (PS 3) Alarm LED is blinking red.
34. Switch ON the HPA 4 PSU circuit breaker (CB4), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 5 PSU (PS 4) Norm LED is blinking green.
o Ensure that the LB HPA 5 PDU (PS 4) Alarm LED is blinking red.
35. Switch ON the HPA 5 PSU circuit breaker (CB5), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 6 PSU (PS 5) Norm LED is blinking green.
o Ensure that the LB HPA 6 PDU (PS 5) Alarm LED is blinking red.
36. Switch ON the HPA 6 PSU circuit breaker (CB6), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 7 PSU (PS 6) Norm LED is blinking green.
o Ensure that the LB HPA 7 PDU (PS 6) Alarm LED is blinking red.
37. Switch ON the HPA 7 PSU circuit breaker (CB7), located on the LB HPA cabinet PDU.
o Ensure that the LB HPA 8 PSU (PS 7) Norm LED is blinking green.
o Ensure that the LB HPA 8 PDU (PS 7) Alarm LED is blinking red.
38. Switch ON the HBE 10A circuit breaker, located on the BMS front panel.
o Ensure that the HBE Power LED is illuminated green and that the internal fan is
rotating continuously.
39. Switch ON the LBE 25A circuit breaker, located on the BMS front panel.
o Ensure that the LBE Power LED is illuminated green and that the internal fan is
rotating continuously. Note: Fan operation will be halted momentarily during the
boot-up process, but will continue to operate continuously.
40. Switch ON the TSC-H 5A circuit breaker, located on the BMS front panel.
41. Switch ON the TSC-L 5A circuit breaker, located on the BMS front panel.
42.
Switch ON t
h
e SPARE 2.5A circuit breaker, located on the BMS front panel.
o Ensure that the BMS alarm LEDs are no longer illuminated red; only the CTR LED
should be illuminated green.
SX03-30000-01-M01
4-4