CAT.ES20-16 B Free-Mounting Cylinder with Air Cushion Seriesø20,CU ø25, ø32 A unique air cushion mechanism has been added to our Series CU free-mounting cylinder.
Free-Mounting Cylinder with Air Cushion Series CU New air cushion mechanism Free-mounting cylinder Series CU now employs an air cushion mechanism. Extended dimensions (compared to the standard CU models) are hardly noticeable. (with rubber bumper) +1.5 to 7mm • Overall height: +0 to 2mm • Overall length: CU hion r cus i a h t wi No air cushion protrusion! • Overall width: not affected rub CU with per um ber b (mm) Bore Extended dimensions size Length Height ø20 2 7 ø25 0 1.
Reduced stroke end impact and noise: New standards to meet consumer demand. Free-mounting 3 types of mounting orientations can be accommodated depending on the installation conditions. Axial mounting (tapped holes) Vertical mounting (body through holes) Lateral mounting (body through holes) Approximately 2.
Free-Mounting Cylinder with Air Cushion Series CU ø20, ø25, ø32 How to Order CU 32 CDU 32 Without auto switch With auto switch 50 A 50 A F9BW Number of auto switches With auto switch (built-in magnet) Bore size 20 25 32 Nil TN TF 1 pc. Without auto switch Nil 25mm ∗ Select auto switch type from the table below. 32mm Type 2 pcs.
Free-Mounting Cylinder with Air Cushion Series CU Specifications Type Fluid Proof pressure Maximum operating pressure Minimum operating pressure Pneumatic (non-lube) type Air 1.0MPa 0.7MPa 0.08MPa Without auto switch: –10°C to 70°C (with no freezing) With auto switch: –10°C to 60°C (with no freezing) Male threads JIS class 2 Ambient and fluid temperature Rod end thread Rod end thread tolerance Stroke length tolerance Piston speed + 1.
Series CU Construction u t !4 w q r !3 !0 !2 i o !5 e y !1 Replacement parts: Seal kits Parts list No. 3 Note Hard anodized Bore size Seal kit no. ø20 CU20A-PS 1 Hard anodized ø25 CU25A-PS 1 Clear chromated ø32 CU32A-PS Aluminum alloy 1 Chromated Stainless steel 1 Carbon tool steel 1 Phosphate coated Carbon steel 1 Nickel plated — (2) Carbon steel 2 Material Aluminum alloy No. of pcs.
Free-Mounting Cylinder with Air Cushion Series CU Dimensions 2-cushion needle 2-port R Q 2-øP through E GA GB 4-NN KA B J JA CA K C CB øD MM A A' H Width across flats L 2-øP through E 4-øT counterbore S + Stroke Z + Stroke (mm) Bore size (mm) 20 25 32 Port size A A' B C CA CB D E GA GB H J JA M5 x 0.8 M5 x 0.8 Rc 1/8 12 15.5 19.5 14 18 22 26 32 40 42 50 62 20 25 31 22 25 31 8 10 12 9 10 11 29 32.5 35 27 22.
Series CU Auto Switch Proper Mounting Positions and Heights for Stroke End Detection D-A9 D-F9 D-F9 W 22 (24.5) 2.8 A 0.5 B W The dimension in ( ) is for D-A93 type. D-A9 V D-F9 V D-F9 WV A 22 (20) 5 (7) B W The dimension in ( ) is for D-F9 V and D-F9 WV. (mm) Bore size (mm) 20 25 32 D-A9 , D-A9 V W A B D-F9 , D-F9 W A B W 18 15 13 (10.5) 22 19 9 22 19 20 11 9 (6.5) 24.5 15 5 24.5 15 7 22.5 13.5 11.5 (9) 26.5 17.5 7.5 26.5 17.5 9.
Free-Mounting Cylinder with Air Cushion Series CU Auto Switch Rail Position B 4-3 4-ø4.2 (mm) A Bore size (mm) A B 20 21 23 25 27 25 32 35 27 Caution – Proximity Installation When free-mounting cylinders equipped with D-A9 or D-F9 type auto switches are used, be sure to provide an extra clearance in addition to what is suggested in the table at right. If the distance between two cylinders is less than the noted value, auto switches may malfunction.
Series CU Auto Switch Specifications Auto Switch Common Specifications Type Reed switch Solid state switch None 3-wire: 100µA or less; 2-wire: 0.8mA or less 1.
Series CU Auto Switch Connections and Examples Basic Wiring Solid state 3-wire, NPN Solid state 3-wire, PNP Brown [Red] 2-wire Brown [Red] Main circuit of switch Blue [Black] Load Brown [Red] Main circuit of switch Black [White] Indicator light, protection circuit, etc. Load Blue [Black] Blue [Black] Blue [Black] Brown [Red] (Power supplies for switch and load are separate.) Brown Brown [Red] [Red] Indicator light, protection circuit, etc.
Reed Switches: Direct Mounting Type D-A90(V), D-A93(V), D-A96(V) Specifications Auto switch part no. D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Wiring type Applicable load 3-wire 2-wire IC circuit, Relay, PLC Relay, PLC IC circuit 24VDC/5 to 40mA 100VAC/5 to 20mA 4 to 8VDC/20mA AC Load valtage Load current range and Max.
Solid State Switches: Direct Mounting Type D-F9N(V), D-F9P(V), D-F9B(V) Specifications Grommet D-F9 , D-F9 V (with indicator light) Auto switch part no. D-F9N D-F9NV D-F9P D-F9PV D-F9B D-F9BV Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular 3-wire Wiring type 2-wire NPN Output type PNP — IC circuit, Relay, PLC 24VDC relay, PLC Power supply voltage 5, 12, 24VDC (4.
Solid State Switches: Direct Mounting Type D-F9NW(V), D-F9PW(V), D-F9BW(V) Specifications Grommet D-F9 W, D-F9 WV (with indicator light ) Auto switch part no. D-F9NW In-line Electrical entry direction D-F9NWV D-F9PW D-F9PWV Perpendicular Perpendicular In-line D-F9BW D-F9BWV In-line 3-wire Wiring type NPN Output type Perpendicular 2-wire — PNP IC circuit, Relay, PLC 24VDC relay, PLC Power supply voltage 5, 12, 24VDC (4.
Series CU Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of "Caution", "Warning", or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices. Caution : Operator error could result in injury or equipment damage. Warning : Operator error could result in serious injury or loss of life.
Series CU Actuator Precautions 1 Be sure to read before handling. Design Warning Design Warning 1. There is a danger of sudden or erratic action by cylinders if sliding parts of machinery are twisted and changes in forces occur. 9. Consider the action when operation is restarted after an emergency stop or an abnormal stop. In such cases, bodily injury may occur, e.g., by catching hands or feet in the machinery, or damage to the machinery itself may occur.
Series CU Actuator Precautions 2 Be sure to read before handling. Mounting Cushion Caution Caution 1. Be certain to align the rod center of the piston axis with the load and direction of movement when connecting. When a cylinder is not properly aligned, the rod and tube may be twisted. This can cause wear on areas such as the inner tube surface, bushings, rod surface, seals, and cause damage to these areas. 2.
Series CU Actuator Precautions 3 Be sure to read before handling. Operating Environment Warning 1. Do not use in environments where there is a danger of corrosion. 2. In dusty conditions or where water or oil splashing is a regular occurrence, protect the rod by installing a rod cover. 3. When using auto switches, do not operate in an environment where there are strong magnetic fields. Maintenance Warning 1.
Series CU Auto Switch Precautions 1 Be sure to read before handling. Design and Selection Warning 1. Confirm the specifications. Read the specifications carefully and use the product appropriately. The product may be damaged or malfunction if it is used outside the range of specifications for load current, voltage, temperature or impact. 2. Take precautions when multiple cylinders are used close together.
Series CU Auto Switch Precautions 2 Be sure to read before handling. Mounting and Adjustment Warning Warning 1. Do not drop or bump. Do not drop, bump, or apply excessive impacts (300m/s² or more for reed switches and 1000m/s² or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires.
Series CU Auto Switch Precautions 3 Be sure to read before handling. Operating Environment Warning 1. Never use in the presence of explosive gases. The construction of our auto switches does not make them explosionproof. Never use them in the presence of an explosive gas, as this may cause a serious explosion 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized if used in such an environment.
Series CU Specific Product Precautions Be sure to read before handling. Refer to pages 12 through 18 for Safety Instructions, Actuator Precautions, and Auto Switch Precautions. Installation and Removal of Snap Rings Selection Caution Caution 1. Use appropriate pliers (C-type snap ring installing tool) for installation and removal of snap rings. 2.
SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE EUROPE NORTH AMERICA AUSTRIA SMC Pneumatik GmbH CZECH SMC Industrial Automation CZ s.r.o. DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatics Finland Oy FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Ipari Automatizálási Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. NETHERLANDS SMC Pnuematics BV. NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp.z.o.o.