Warning - DO NOT use a pin or wire when
cleaning the burner orifice as damage can occur to
the precision opening. This can cause damage to
the refrigerator or create a fire hazard. It will also
create extremely dangerous levels of carbon
monoxide.
o The inlet & outlet gas fittings on the refrigerator need to be checked
for leaks. Apply a non-corrosive bubble solution to the fittings and
observe for leaks. The safety valve will not allow gas pressure to any
connections between it and the burner orifice. These fittings must be
checked while burner is in operation (gas flow will be present between
safety valve and burner head).
WARNING The gas button D (Fig. #5) must be
manually depressed to allow gas pressure to flow to the
burner orifice. Be sure to apply the leak check solution
before depressing the safety shut–off. DO NOT allow
any open flame, sparks, smoking, etc. in the area of the
test. DO NOT depress safety shut-off for over 30 seconds.
o If a leak occurs, then allow ten minutes to dissipate from the burner
area. Fix leak then light the burner according to the instructions under
GENERAL OPERATING INSTRUCTIONS GAS OPERATION, CHAPTER 3.